29.
Brake -
When the button is illuminated a brake effect is activated, pressing the play button while the track is playing will
slowly bring the track to a stop. Pressing the play button in pause mode will start the track slowly the will climb to correct
speed.
30.
Reverse -
When this button is illuminated the track will play backwards.
31.
Time -
This button will toggle between time elapsed and time remaining, this will be displayed in the screen.
32.
Tap -
Press the tap button continuously to the beat of the music to activate the manual BPM counter, this will determine
the speed of the track and give a visual BPM (beats per minute) value in the display.
33.
Play/pause
- This button will play or pause the track.
34.
Mains power cable input
35.
Balanced outputs -
Connect balanced XLR leads to the amp. Controlled by master volume slider.
36.
RCA master outputs -
Connect RCA/phono leads
to the amp. Controlled by master volume.
37.
Booth -
Connect
RCA/phono leads
to the amp. Controlled by booth volume.
38.
Rec -
Connect
RCA/phono leads
to a tape deck or recording device.
39.
Source inputs -
Connect either phono or line level inputs here. Please note phono is for turntables only, these must not
be connected to a line level source input. Likewise line level source must not be connected to phono inputs.
40.
Earth -
Use this tag to connect the earth tag lead on turntables to reduce audio hum. This is for turntable earth only and
should not be used as a main earth grounding point.
Specifications
Input terminal (input level/impedance)
CD/line
300mV/22k
Phono
5mV/47k
Main mic
5mV/3k
Mic
5mV/3k
Frequency characteristics
CD/line/phono/mic
20Hz to 20kHz
SN ratio
CD/line
86dB (with effects off)
Phono
76dB
Mic
69dB
Total harmonic distortion rate
CD/line/phono
76dB
Cross talk
Over 70dB
Channel equalizer
Hi
+12dB, -24dB (13kHz)
Mid
+12dB, -24dB (1kHz)
Low
+12dB, -24dB (70Hz)
Microphone equalizer
Hi
+12dB, -12dB (10kHz)
Mid
+12dB, -12dB (1kHz)
Low
+12dB, -12dB (100Hz)
Power supply voltage
AC100-240v (10kHz)
Power consumption
20w
Operating temperature
+5 c to +35 c
Operating humidity
5% to 85%
Содержание KAP1200 USB