KAM Systems i2 Series Скачать руководство пользователя страница 4

Powered by KAM Systems Limited

www.nursecallshop.co.uk

User Guide

i

2

 Series

Technical Specifications

Optical

Detector type: Dual element low noise pyroelectric sensor.

Number of curtain beams: 2

Range settings: Long (6m), Medium (4m) and short (2m).

Electrical

Internal Battery: 3v lithium battery, type CR123A.

Nominal battery capacity: 1450 mA/h

Battery life: 3 years (for typical use)

Microprocessor: 8-bit, low power CMOS

Functional

LED lights for about 3 seconds upon transmission of alarm.

LED flashes during the power-up stabilization period.

Alarm period:  approx. 3 seconds

Rearm timer: Rearms the detector 2 minutes after the last alarm

Wireless Motion Sensor installation and user guide

i

2

 Series

User Guide

Powered by KAM Systems Limited

www.nursecallshop.co.uk

Product Limitations

a. Receivers may be blocked by radio signals on or near their 

operating signals.

b. A receiver can only respond to one signal at a time.

c. Wireless equipment should be tested regularly whether there 

are sources of interference and to protect against faults.

All reasonable care has been taken to ensure that the information contained in this publication is accurate as at the date of printing. Such information is nevertheless liable to variation in the event 

of changes occurring subsequent to the date of printing in the products, services or statements referred to in this publication.  Copyright KAM Systems Limited 2016

•  The red LED will show the user if the slot is taken 

by an existing device or free to add a new device. 
If the RED LED pulses the slot is free to add a new 
device. If the RED LED is solid the slot is currently 
occupied by a device.

•  Once an occupied slot is found, press the delete 

button once located on the side of the receiver 
unit. The solid red LED will change to a Pulsing 
LED. This signifies that the slot is now empty.

Once completed, switch from LEARN back to 
OPERATE to continue with normal function.
TEST your work by activating your Pendant / 
Sensor. The red Led will NOT flash.

General guidelines 

Wireless systems are a very reliable and are tested 
to high standards. However, due to their low 
transmitting power and limited range, there are some 
limitations to be considered. 
Please keep the CURTAIN SENSOR away from:

•  Any constant heat source
•  Direct sunlight
•  Electrical mains cable
•  Unstable surfaces
•  Open windows