Powered by KAM Systems Limited
www.nursecallshop.co.uk
User Guide
i
2
Series
Technical Specifications
Optical
Detector type: Dual element low noise pyroelectric sensor.
Number of curtain beams: 2
Range settings: Long (6m), Medium (4m) and short (2m).
Electrical
Internal Battery: 3v lithium battery, type CR123A.
Nominal battery capacity: 1450 mA/h
Battery life: 3 years (for typical use)
Microprocessor: 8-bit, low power CMOS
Functional
LED lights for about 3 seconds upon transmission of alarm.
LED flashes during the power-up stabilization period.
Alarm period: approx. 3 seconds
Rearm timer: Rearms the detector 2 minutes after the last alarm
Wireless Motion Sensor installation and user guide
i
2
Series
User Guide
Powered by KAM Systems Limited
www.nursecallshop.co.uk
Product Limitations
a. Receivers may be blocked by radio signals on or near their
operating signals.
b. A receiver can only respond to one signal at a time.
c. Wireless equipment should be tested regularly whether there
are sources of interference and to protect against faults.
All reasonable care has been taken to ensure that the information contained in this publication is accurate as at the date of printing. Such information is nevertheless liable to variation in the event
of changes occurring subsequent to the date of printing in the products, services or statements referred to in this publication. Copyright KAM Systems Limited 2016
• The red LED will show the user if the slot is taken
by an existing device or free to add a new device.
If the RED LED pulses the slot is free to add a new
device. If the RED LED is solid the slot is currently
occupied by a device.
• Once an occupied slot is found, press the delete
button once located on the side of the receiver
unit. The solid red LED will change to a Pulsing
LED. This signifies that the slot is now empty.
Once completed, switch from LEARN back to
OPERATE to continue with normal function.
TEST your work by activating your Pendant /
Sensor. The red Led will NOT flash.
General guidelines
Wireless systems are a very reliable and are tested
to high standards. However, due to their low
transmitting power and limited range, there are some
limitations to be considered.
Please keep the CURTAIN SENSOR away from:
• Any constant heat source
• Direct sunlight
• Electrical mains cable
• Unstable surfaces
• Open windows