background image

31

GB

AL C

AL F

Control board

AL C

AL F

1

5

6

7

9

4

2

8

11

10

3

12

1.  Temperature or power decrease
2.  Temperature or power increase
3.  Key On/Off
4.  Receiver
5.  Led alarm ALC
6.  Led alarm ALF
7.  Led chrono-thermostat
8.  Led temperature ok
9.  Led pellets loading
10. Led resistance
11. Display LED 7 segments
12. Led On/Off

Display keys and functions

1. Using the key on the menu Set temperature, you can 
decrease the temperature from a maximum value of 40 °C 
to a minimum value of 7 °C.
With the key on the menu Set power, you can decrease the 
working power from a maximum value of 5 to a minimum 
value of 1. 

2. Using the key on the menu Set temperature, you can 
increase  the  temperature  from  a  min.  value  of  7°C  to  a 
max. value of 40°C.
With the key on the menu Set power, you can increase the 
working power from a min. value of 1 to a max. value of 5.

3. Keep the key pressed for 2 seconds to switch the stove 
on or off.

4. Sensor receiving the settings of the remote control.

5. The led blinks in the event of a malfunction or alarm.

6. The led blinks in the event of a malfunction or alarm.

7. This means the automatic single or daily programming 
of the switching on or off of the stove is on.
The  automatic  programming  can  be  set  only  with  the 
remote control (optional).

8. This is on when the stove reaches the set temperature. 
In  this  case  you  will  read  the  word  “Eco”  and  the  set 
temperature on the display.

9. This led blinks every time the stove is loading pellets.

10. This led is on only while the stove is lighting up in order 
to indicate that the resistance is warming the air which will 
fire the pellets.

11.  On  the  display  you  can  read  the  different  working 
functions of the stove, the room temperature and the set 
working power. In the event of a malfunction, the display 
shows  the  relative  error  codes  (see  paragraph  on  alarm 
codes).

12. This led indicates the different phases of the stove:
- it is on if the stove is switched on and working
- it is off if the stove is switched off
- it blinks if the stove is switching off

Stove setting

How to change the wished room temperature

Join  the  following  procedure  to  change  the  wished 
temperature: press the key 

 (1) once to enter the menu 

and set temperature. You will read the word “Set” and the 
wished temperature on the display. Use the keys 

 (2) 

and 

 (3) to increase or reduce the wished value.

The stove will leave the menu Set temperature automatically 
as soon as you do not work on it for some seconds.

How to change the working power

Join the following procedure to change the working power: 
press the key 

 (1) once to enter the menu and set the 

working power. You will read the word “Pot” and the range 
of 5 possible powers on the display. Use the keys 

 (2) 

and 

 (3) to increase or reduce the wished value.

The  stove  will  leave  the  menu  Set  working  power 
automatically  as  soon  as  you  do  not  use  it  for  some 
seconds.

AL C

AL F

1

2

2

3

3

1

Содержание Mignon 6

Страница 1: ...INSTALLER USER MANUAL For Petite 6 Air Stove...

Страница 2: ...the stove door handle sides can reach high temperatures Therefore pay attention and use the proper precautions above all in the presence of children elderly or disabled persons and animals Assembly m...

Страница 3: ...servance of the instruc tions contained herein We decline every responsibility derived from improper use of the stove from incorrect use by the user from un authorized modifications and or repairs fro...

Страница 4: ...eaning and maintenance to be performed by the user should not be made by children without supervision Do not use the stove as a ladder or scaffold Do not put clothes to dry on the stove Any clothes ha...

Страница 5: ...t not be less than 30 m3 The air must come in through permanent openings made in walls in proximity to the stove which give onto the outside with a minimum cross section area of 100 cm2 These openings...

Страница 6: ...nless steel pipe must not be used At the bottom of the flue pipe provide an inspection cap to allow periodic checking and cleaning which must be done annually Make a gas tight connection to the flue p...

Страница 7: ...different dimensions and forms according to the angle of inclination of the roof so it is necessary to adopt minimum heights The chimney cap must be a wind proof type and must be above the ridge Event...

Страница 8: ...you will read the word Eco and the set temperature on the display 9 This led blinks every time the stove is loading pellets 10 This led is on only while the stove is lighting up in order to indicate...

Страница 9: ...automatic switching on of the stove program 1 OFF1 Using this key you can set a single time schedule for the automatic switching off of the stove program 1 ON2 Using this key you can set a single time...

Страница 10: ...fferent selections from the remote control the stove will restart working as it did before you activated the turbo function Keep the key TURBO 1 pressed for at least two seconds to activate this funct...

Страница 11: ...n 20 minutes between the switching off and subsequent switching on of the stove In this way the unit will have time to arrange a complete cooling phase in the event this minimal interval is not calcul...

Страница 12: ...reheating the resistor preceding lighting LOAD WOOD the stove is loading pellets On the control board the LED resistance is on FIRE ON The stove is in the flame stabilization phase flame present ON 1...

Страница 13: ...Data Dis A DESCRIZIONE Modifica B C D E F G MZ ASSIEME 6KW ESTETICA MIGNON 41547 g 17 05 2016 Via delle Arti e dei Mestieri 1 3 H I Trattamento 4705001 v e R e c i d o C 1 5 770 487 32 431 25 174 158...

Страница 14: ...e weight Kg 45 N Test Report K18532016T1 It is recommended that the control of emissions after installation The pellets are cylinders of compressed wood produced from sawdust and wood processing chips...

Страница 15: ...erature the display will show MODULATION Stove start up We highly recommend to turn to our Authorized Service Centre for the installation and the first ignition of the device as it not only carries ou...

Страница 16: ...cur also when there is not enough pellets flow to light up the unit Press the key On Off on the control board to reset the alarm Wait until the cooling phase is completed clean the brazier and start u...

Страница 17: ...Cleaning the glass The glass is a self cleaning type therefore while the stove is working a veil of air is blown across its surface to remove ash and dirt nevertheless over a period of several hours...

Страница 18: ...ar and below the stove Eventual deposits of dust or ash on the blades of the fan can cause an imbalance in the fans leading to noisy performance It is therefore necessary to clean the fans at least on...

Страница 19: ...ollection compartment Cleaning ash tray Cleaning the door and glass Cleaning the interior heat exchanger smoke fan compartment Cleaning complete exchanger Clean T to exhaust Flue Door gasket ash Inter...

Страница 20: ...body stove RESTART PELLET Reduction motor if the motor stops the thermostove continues to function until the flame goes out for lack of fuel and until It has cooled down to the minimum level Flue gas...

Страница 21: ...pted 6 Card defective 1 Check that the power cord is connected 2 Use the switch back to operate it 3 Unplug the stove from the power outlet for about one minute and then turn on If the problem persist...

Страница 22: ...se the drawer ashtray 10 Perform periodic cleaning 11 Check the operation of the extractor flue 12 Contact an authorized service center 13 Make sure the place of stowage pellet and re place it with a...

Страница 23: ...xhaust fumes Contact your Authorized Service Center 7 Check the quality of the pellets Contact your Authorized Service Center 8 Increase the level in the parameters relating to the speed of the fan ex...

Страница 24: ...oreign objects 7 Close the door or replace the gaskets with original 8 Change the type of pellet recommended by the manufacturer Sometimes depending on the type the stage of adjustment of the paramete...