7
7.1 Alarm signals
In the event of a working defect, the system informs the user about the type of failure occurred. The following table summarises
the alarms, kind of problem and possible solution:
Display
Kind of problem
Solution
ALAR 1
BLACK OUT
There is no power supply
As soon as the power supply is back, the Insert
starts a cooling cycle: it will be necessary to
restart it manually
ALAR 2
PROBE
EXHAUST
The smokes sensor is broken or not
connected to the pcb
Contact an Authorized Assistance Center
ALAR 3
HOT
EXHAUST
Smokes temperature too high
Switch off the Insert, allow it to cool down
and perform ordinary cleaning. If the problem
persists, contact an Authorized Assistance Center
for cleaning the Insert and the flue
ALAR 4
FAN
FAILURE
Smokes extractor blocked or broken
Contact an Authorized Assistance Center
ALAR 5
NO
LIGHTIN
The Insert cannot start up
This is the first light-up
Fill in the tank with pellets
Start up again
ALAR 6
NO
PELLET
The pellet Insert switched off while
working
Fill in the tank with pellets
ALAR 7
SAFETY
THERMAL
The water temperature exceeds 100°C.
Clean the inert and the flue. Reset the thermost
manually. If the problem persists, contact an
Authorized Assistance Center
ALAR 8
FAILURE
DEPRESS
Obstructed flue
Clean the flue or check there are no obstructed
grids near the smokes exhaust
SERV
The Insert has worked for 1200 hours.
Supplementary maintenance required
Contact an Authorized Assistance Center
Regular checks should be carried out by the user, who should only contact the Authorized
Assistance Center if no solution is found.
EN
Содержание Chiara 15
Страница 22: ...20 NOTE Cod 001030A EN...