background image

2

1.0 Norms and declarations of conformity 

Our company declares that the insert conforms to the following norms for the EC European Directive labelling:

2014/30 UE (regulation EMCD) and following amendments;

2014/35 UE (Low Voltage Directive) and following amendments;

2011/65 EU (RoHS 2 directive);

The Rules of Construction Products (CPR-Construction Products Regulation) No. 305/2011 regarding the construction world;

For installations in Italy, please refer to UNI 10683/98 or following changes. For the water-thermo-sanitary equipment, let the 

installer give you the conformity declaration in compliance with L. 37/2008. While installing the unit respect the local, national 

and Europen rules;

EN 55014-1; EN 55014-2; EN 61000-3-2; EN 61000-3-3; EN 60335-1; EN 60335-2-102; EN 62233, EN 50581.

1.1 Safety Information

Please carefully read this use and maintenance manual before installing and operating the insert! 

If clarification is needed, please contact the dealer or the Authorized Assistance Centre.

• The pellet insert must only be operated in living environments. This insert, being controlled by an electronic board, 

permits a completely automatic and controlled combustion; the exchange, in fact, regulates the lighting phase, 5 power 

levels and the shut down stage, guaranteeing the safe operation of the insert;

• The basket used for combustion allows most of the ash produced by the combustion of the pellets to fall into the collec-

tion compartment. Nevertheless, check the basket daily, given that not all pellets have high quality standards (use only 

quality pellets recommended by the manufacturer);

• The glass is equipped with a special circulation of air for self-cleaning, but still, it is not possible, after several hours of 

operation, to keep a light grey patina from forming on the glass. This also depends on the type of pellets used. Some 

pellets deposit more ash than others.

1.2 Responsibility

With the delivery of the present manual, we decline all responsibility, both civil and penal, for accidents deriving from the 

partial or total lack of observance of the instructions contained herein.

We decline every responsibility derived from improper use of the insert, from incorrect use by the user, from unauthorized 

modifications and/or repairs, from the use of replacement parts that are not original for this model.

The manufacturer declines every civil or penal, direct or indirect responsibility due to:

• Lack of maintenance;

• Failure to observe the instructions contained in the manual;

• Use in non-conformity with the safety directives;

• Installation in non-conformity with the norms in force in the country;

• Installation by unqualified or untrained personnel;

• Modifications and repairs not authorized by the manufacturer;

• Use of non-original replacement parts;

• Exceptional events.

!

• The insert must only be fed with quality 6 mm diameter pellets of the type 

recommended by the manufacturer;

• Before making the electrical connection of the insert the discharge tubes 

must be connected with the flue;

• The environment where the insert is installed must have a sufficient ex-

change of air;

• Never open the door of the insert while it is operating;
• When the insert is operating, the surfaces, glass, handle and tubes beco-

me very hot: during operation do not touch these parts without adequate 
protection;

EN

Содержание Chiara 15

Страница 1: ...USER MANUAL Paola 13 Chiara 15 Insert Air Stoves Instructions for the correct use and maintenance of your Kalor wood pellet air dry stove Distribution and warranty in Ireland by...

Страница 2: ...port a nationwide network of Authorised Technicians who are specially trained on Kalor wood pellet stoves and boilers This ensures that your stove can be correctly installed commissioned maintained an...

Страница 3: ...e Although the carefully studied design and the risk analysis done by our company has permitted the realization of a safe product in any case before effecting any operation on the insert it is recomme...

Страница 4: ...use only quality pellets recommended by the manufacturer The glass is equipped with a special circulation of air for self cleaning but still it is not possible after several hours of operation to kee...

Страница 5: ...ould produce sparks if handled incorrectly Only authorized technicians can resolve possible problems Do not remove any screws from the fire chamber without first lubricating them well Never open the g...

Страница 6: ...ir proper operation this can lead to the termination of the guarantee and its producer responsibility For our products use pellets diameter 6 mm length 30 mm and a maximum of 6 and A1 certified accord...

Страница 7: ...here is a warning EN Remove any components which might burn from the firebox and from the glass various instructions and adhesive labels Never remove the protection grille in the hopper When filling d...

Страница 8: ...or and the cochlea engine are active BRAZIER CLEANING The Insert is cleaning the basket The smoke extractor runs at maximum speed and the pellet load is at minimum WORK The Insert is working in this c...

Страница 9: ...for cleaning the Insert and the flue ALAR 4 FAN FAILURE Smokes extractor blocked or broken Contact an Authorized Assistance Center ALAR 5 NO LIGHTIN The Insert cannot start up This is the first light...

Страница 10: ...1 and 2 select whether or not to activate the thermostat on off which allows you to program the automatic ignition of the Insert Once the thermostat is activated deactivated press button 4 OFF and con...

Страница 11: ...saturday prog 1 on off 10 sunday prog 1 on off 11 start program 2 hour 12 stop program 2 hour 13 monday progr 2 on off 14 tuesday progr 2 on off 15 wednesday prog 2 on off 16 thursday prog 2 on off 1...

Страница 12: ...ccording to the following table where the OFF setting tells the clock to ignore the command The weekly programmer has 4 independent programmes whose final effect is composed of the combination of the...

Страница 13: ...FRIDAY PROGRAM 1 on off 02 03 09 SATURDAY PROGR 1 on off 02 03 10 SUNDAY PROGR 1 on off PROGRAMME 2 menu level selection meaning possible values 03 03 11 START PROGRAM 2 activation time time OFF 03 0...

Страница 14: ...to reset the alarm Wait until the cooling phase is completed Clean the brazier and start a new light up These alarms remind you that the brazier must be cleaned and installed correctly before switchi...

Страница 15: ...tion is set by default to OFF To activate this feature press SET 3 to access it STAND BY function is set by default to OFF 1 on the display you will see STAN BY MODE ON Press SET 3 to confirm and then...

Страница 16: ...ines any responsibility Eventual variations in the colour of the metal parts can be caused by an incorrect use of the insert 11 0 Cleaning and maintenance 11 1 Ordinary cleaning to be done every day o...

Страница 17: ...e holes by using a pointed tool not included with the insert This operation is made particularly necessary before every lighting the first several times and above all if using pellets that differ from...

Страница 18: ...can in any case cause the glass to become dirty NOTE If the glass is broken do not attempt to light the insert 11 7 Ash box Open the door turn the two fastening knobs and remove the tray Remove all th...

Страница 19: ...ual ash or dust rests Installa the insert again Place it on the support and push it slowly until it reaches the apposite check pin Check that the flue system lies perfectly in the T pipe Pict 20 how t...

Страница 20: ...C the glass can break only from a strong impact or from improper use Do not slam the door or hit the glass In case of breakage replace the glass only with an original replacement furnished by the Aut...

Страница 21: ...e can only take place following the unquestionable decision by the manufacturer in special cases 3 The Company declares no responsibility for any damage that may directly or indirectly result in perso...

Страница 22: ...20 NOTE Cod 001030A EN...

Страница 23: ...cturer It is very important to understand that any and all warranty claims may be rejected should your stove boiler not be commissioned by one of our Authorised Technicians See below for further detai...

Страница 24: ...Wood Pellet Stoves ie Newport Co Mayo Ireland Tel 086 012 7744 Email info woodpelletstoves ie Web www woodpelletstoves ie...

Отзывы: