72
Scheme 02 :
the thermostove is connected to a technical w
ater puffer
.
The thermostove is switched off when the upper contact (thermostat) is satisfi
ed.
The thermostove is switched on when the lower contact (thermostat) is not satisfi
ed.
The heating w
ater will then be tak
en from this puffer by means of the pumps and the relays are not controlled by the thermostove control unit.
a)
a)
To set the thermostove w
ater temper
ature
, press the
. Increase or decrease the degrees with the
and
.
b)
To set the desired temper
ature in the room (using the probe on the board) press the
ke
y.
Increase or decrease degrees with the
and
ke
ys.
c)
To set the work power
, press the
k
ey and adjust it with the k
eys
and
.
The rinsing from the stand-by state occurs automatically when a heat increase is required to return to satisfy the chosen stand-by condition (when this is set to ON)
or when there is a risk of hot w
ater inside the puffer
.
II
I
The scheme is indicative and w
ants to
demonstr
ate only the components that
can be managed by the thermostove
.
Any relay pumps must be controlled
separ
ately from the thermostove
.
I
=
ON / OFF higher thermostat
on
Technical w
ater Puffer
.
II
=
ON / OFF lower thermostat
on
Technical w
ater Puffer
.
3 vi
e
3 wa
y
comune - N
common -
N
Lato sanitatio
DHW side
Lato riscaldam.
heating side
Sond
a
sup.
puffe
r
Puffer
uppe
r
prob
e
Termostat
o
estern
o
External
thermostat
Sonda accumulo
sanitario o sonda inf. puffe
r
DHW probe or puffer
lower prob
e
1
2
3
4
5
Terminal block:
numerical correspondence
for the v
arious electrical connections
.
6
EN