11
rope, take out old insert and replace it with a new rubber bladder. A
special attention must be paid to the location of the bladder valve. The
valve must be placed in the opening of the leather cover.
F)
Bulb replacement, GAME button
In case of bulb failure in the GAME button one should take out micro-
switch from the casing (by slight turn and then pull) and then proceed
with bulb replacement [bulb spec: 12 Volt & 3 Watt].
G)
Fuse replacement
Machine is equipped with two long term fuses. One at power supply
assembly and the second one on the main electronic board [specs: 250V &
4 A]. In case of short circuit situation and/or insufficient power supplied to
the electronic main board one should first check the fuses and if they are
burned, then proceed with replacement. Make sure fuses used to replace
old one have the same specifications.
H)
Position of the Arm protector
DO NOT PLAY THE GAME WITHOUT PROPERLY
PLACED ARM PROTECTOR.
The position of the arm protector should be like on the picture below: