5.10 Finishing the Kalfire W53/50S, W66/48S and
W90/47R5.10 models
The surround above the Kalfire w53/50r and w66/48s must have
at least 2 mm of play, in relation to the trim above the door.
Front finish
The front of the Kalfire w53/50r, w66/48s and w90/47s
can be finished in two ways:
1. Mount the platform under the steel design trim.
2. Mount the platform against the steel design trim (at the
same height).
CAREFUL! The platform may not touch the steel design
trim; leave at least 2 mm between the platform and the
steel design trim.
Platform
Table 5a: Kalfire w Technical data
Steel design
trim
Kalfire type
W45/48F W53/50R
W60/51F
W70/33F
W71/62F
W85/40F W100/61F W105/47F
Type of plate
p8-2018-
0071
p8-020-
2018
p8-003-
2015
p8-017-
2015
p8-025-
2011
p8-001-
2015
p8-066-
2010
p8-019-
2015
Inspection body
2013
1004
1004
1004
1004
1004
1004
1004
Standard
en13229
a2
en13229
a2
en13229
a2
en13229
a2
en13229
a2
en13229
a2
en13229
a2
en13229
a2
Output (kW)
9.2
6.5-13
6.6-13.2
6-12
8-16.0
7.4-14.8
8.8-17.6
8.8-17.6
Flue gas mass flow (g/s)
x
14.04
11.3
10.3
12.7
13.2
17.34
15.9
Heat output (%)
84
80%
81
80
83
81
80
81
Flue gas temperature (°C)
238
230
260
282
302
257
255
245
CO at 13%O2 (%)
0.073
0.09
0.08
0.09
0.1
0.06
0.09
0.08
CO2 content (%)
10.831
8.09
10.1
10.5
10.6
9.72
8.8
9.46
Dust content at 13%O2 (mg/nm³)
22
33
13
34
11
17
22
11
NOx at 13%O2 (mg/nm³)
47
99.55
119
87
113
80.7
116
118
CnHm at 13%O2 (mg/nm³)
75
60
58
74
61
25.6
90
60
Min. flue draught (Pa)
12
12
12
11
12
11.6
13
12
Insulation: side panel (cm)
5
5
10
10
10
10
5
5
Insulation according to AGI Q 132
(Table 1, page 4) Rear panel (cm)
5
10
10
10
10
10
5
5
Base insulation (cm)
0
0
0
0
0
0
0
0
Roof insulation (cm)
9
9
9
9
9
9
9
9
Flue exit connection (mm)
¢150
200
¢180
¢180
¢250
¢200
¢250
¢250
Combustion air connection (mm)
1 × Ø150
mm
1x180
1 × Ø150
mm
2× Ø150
mm
2 × Ø150
mm
2× Ø150
mm
2× Ø150
mm
2× Ø150
mm
Convection connection inlet
(mm)
2× Ø150
mm
2x150
2× Ø150
4× Ø150
4× Ø150
4× Ø150
4× Ø150
4× Ø150
Convection connection outlet
(mm)
2× Ø150
2 x 150
2× Ø150
4× Ø150
4× Ø150
4× Ø150
4× Ø150
4× Ø150
Weight (kg)
180
327
226
210
271
257
430
328
31