Kalfire type
W65/38C
W90/47C
W66/48S
W90/47S
W80/52T
W105/47T
Type of plate
p8-020-
2014
p8-048-
2010
p8-054-
2015
p8-004-
2013
p8-070-
2015
p8-007-
2010
Inspection body
1004
1004
1004
1004
1004
1004
Standard
en13229
a2
en13229
a2
en13229
a2
en13229
a2
en13229
a2
en13229
a2
Output (kW)
6.5-13
7.5-14.9
6.7-13.3
9.0-18
8.4-16.8
8,8-17,6
Flue gas mass flow (g/s)
10.2
14.95
13.04
15.5
15.8
20.87
Heat output (%)
82
80
80
82
80
78
Flue gas temperature (°C)
257
241
247
248
262
277
CO at 13%O2 (%)
0,1
0.10
0.07
0,1
0,09
0.10
CO2 content (%)
10.8
8.6
8.8
9.9
9.3
7.4
Dust content at 13%O2 (mg/nm³)
35
20
10
30
12.8
25
NOx at 13%O2 (mg/nm³)
94
138
111
112
119
150
CnHm at 13%O2 (mg/nm³)
82
93
49
78
65
110
Min. chimney draft (Pa)
13
13
12
12
12
11
Insulation: Side panel (cm)
5
10
10
5
-
-
Insulation according to AGI Q 132
(Table 1, page 4) Rear panel (cm)
5
10
10
10
10*
10*
Base insulation (cm)
0
0
0
0
0
0
Roof insulation (cm)
9
9
9
9
9
9
Flue exit connection (mm)
¢180
¢250
¢200
¢250
¢200
¢250
Combustion air connection
(mm)
2× Ø150
mm
2× Ø150
mm
2× Ø150
mm
2× Ø150
mm
2× Ø150
mm
2× Ø150
mm
Convection connection inlet
(mm)
2× Ø150
mm
4× Ø150
mm
2× Ø150
mm
2× Ø150
mm
2× Ø150
mm
4× Ø150
mm
Convection connection outlet
(mm)
2× Ø150
mm
4× Ø150
mm
2× Ø150
mm
2× Ø150
mm
2× Ø150
mm
4× Ø150
mm
Weight (kg)
270
320
270
360
385
435
Table 5b: Kalfire w Technical data
32