Error code Cause
Solution
Lack of ionisation
detection during
ignition
If no flame is visible during ignition, but a spark
appears at the ignition rod (the V symbol on the
burner in the fire):
The gas pressure in your home is insufficient or the
gas valve is defective. In either case, contact your
installer.
08A
Lack of ionisation
detection during
ignition
If no flame is visible during ignition, and no
spark appears at the ignition rod (the V symbol
on the burner in the fire):
Check the fire to ensure that there is
no contact between the ignition rod
(the V symbol in the burner) and the
other elements.
Check that the cable is correctly
plugged into the technical unit (see
‘ionisation’ in section 20: Wiring
diagram).