background image

11

 

 WARNING

 Should the floor in 

front of the fireplace consist of 
combustible material and the 
distance from the underside of the 
combustion chamber to the floor 
be smaller than 10 cm, a heat-
resistant fireguard floor plate 
larger than 30 cm or a stone should 
be placed.

Fig. 1:

 Safe zone

Danger of combustion
 

 FIRE  HAZARD! 

Do not touch the 

appliance! The gas fire is hot when 
switched on or just switched off. 
Ensure extra safety precautions 
and safety measures if less able-
bodied persons, elderly people 
and/or children have access to the 
fireplace. Only the remote control 
and the technical unit can be used 
without fear of danger due to 
combustion.

Danger caused by fumes or gas leaks
  

DANGER OF EXPLOSION! 

  Fumes 

and/or gas leaks can cause  life-
threatening situations.  Fumes can 
be the cause of carbon  monoxide 
poisoning and gas leaks are an 
explosion risk. 

If you notice fumes or gas, take the 
following precautions:

1.

  Switch off the gas fire.

2.

  Close the main gas valve.

3.

  Open windows and doors.

4.

   Advise an approved installer of the 

issue.

  

 DANGER OF EXPLOSION!

 Should 

damage occur, close the gas valve. 
Do not use the gas fire if a glass 
panel is cracked, is not in place or 
incorrectly mounted.

The gas fire needs a permanent power 
supply. Interrupting the power supply 
can impact safety precautions. 

The risk of discolouration
 

 CAREFUL! 

After the convection 

system of the fireplace has been 
heated, air particles, cigarette 
smoke, candles and oil lamps 
can cause discolouration of walls 
and ceilings. Ensure sufficient 
ventilation in the room in which the 
gas fire is installed.

30 cm

40 cm

100 cm

20°

 

20°

 

Содержание G160/41F

Страница 1: ...User instructions BALANCED FLUE GAS FIRES DON T COMPROMISE AU ...

Страница 2: ......

Страница 3: ...Balanced flue gas fires Kalfire G80 48F Kalfire G85 44C Kalfire G90 44S Kalfire G160 41F Kalfire G165 37C Kalfire G170 37S for gas type NG ULPG and NZLP Version 03 2021 ...

Страница 4: ......

Страница 5: ... and removing the 30 guard mesh screen Contents 1 General information 7 1 1 Foreword 7 1 2 Pictograms 8 1 3 Warranty 8 2 Safety 10 2 1 Safety instructions for decorative elements 10 2 2 Safety related to use 10 2 3 Three safety measures for the gas fire 12 3 Description 13 3 1 Gas fire description 13 4 Operation 14 4 1 Replacing the batteries 14 4 2 Using the iMatch remote control 14 4 3 Setting d...

Страница 6: ...6 ...

Страница 7: ...r the account of the user Copyright 2020 Kalfire B V Geloërveldweg 21 Belfeld The Netherlands 1 General information The following sections provide general information about the gas fire Foreword Pictograms Warranty 1 1 Foreword About this manual This user instruction has been written for the users of the gas fire A seperate Installation Manual accompanies this User Instructions The user instructio...

Страница 8: ...arranty 6 Should disruption occur within the warranty period caused by a manufacturing error or material defect Archifire Fireplaces will deliver the components needed for repair to the technical fitter of the gas fire without paying compensation for dismantling or 1 2 Pictograms The following pictograms are used in this manual IMPORTANT Warning for flammable material Mitigate the risk of an explo...

Страница 9: ...nical fitter approved by Archifire Fireplaces be unable to rectify the problem covered by the warranty then he is entitled upon his own express desire to requestArchifire Fireplaces to assume responsibility for doing so 9 Verification or repair of an entire gas fire or parts thereof can only take place by appointment after prior consultation between Archifire Fireplaces and the technical fitter ap...

Страница 10: ...le materials such as curtains and furniture are at least 100 cm from the fireplace If a fireguard is used this distance must be at least 40 cm 2 Safety The following sections provide safety information about the gas fire Safety regulations for decorative elements Safety related to use Three safety measures for the gas fire 2 1 Safety instructions for decorative elements FIRE HAZARD The decorative ...

Страница 11: ...EXPLOSION Fumes and or gas leaks can cause life threatening situations Fumes can be the cause of carbon monoxide poisoning and gas leaks are an explosion risk If you notice fumes or gas take the following precautions 1 Switch off the gas fire 2 Close the main gas valve 3 Open windows and doors 4 Advise an approved installer of the issue DANGER OF EXPLOSION Should damage occur close the gas valve D...

Страница 12: ...ity The appliance will stay in a blocked position if no flame is detected after three automatic ignition attempts error code 08A The block will take effect after one ignition attempt with gas type NZLP This block can twice be unlocked manually with the remote control If no flame is detected after two manual releases the appliance will remain blocked for 24 hours a lock out code 08F In that case yo...

Страница 13: ...elivered with an optional hybrid function The gas fire s fuel bed is equipped with LED lighting that simulates a bed of natural embers The lighting generates an atmospheric imitation of the glow of a real wood fire The hybrid function can also be switched on separately without engaging the Prestige burner The Kalfire G with a 3D burner generates an elongated and horizontal flame pattern well suite...

Страница 14: ...of the gas fire Replacing the batteries Using the iMatch remote control Setting the day and time Confirming the transmission strength Switching the gas fire on and off Adjusting the flame intensity Selecting the thermostat or manual operating programme Regulate the flame intensity by thermostat Programming time segments 4 1 Replacing the batteries Insert or replace the remote control AA batteries ...

Страница 15: ...ifications such as disruptions 9 Warning signals related to disruptions 10 Time segments 11 Thermostat mode 12 Manual programme default mode Buttons a and buttons b Left button and right c Centre button d On off button e Parameter configuration button P Fig 2 Remote control Key of symbols 1 Indicates the time and status when switching the appliance on or off OK the fireplace is switched on WARM th...

Страница 16: ... will stop flashing after the ignition programme 6 The gas fire flame is alight and operational 7 Press for approximately two seconds to extinguish the gas fire flame 4 3 Setting day and time Setting day and time Carry out the following steps to change the day and time settings 1 Hold down the P button until the time display starts flashing 2 Change the hour with the or button and confirm the chan...

Страница 17: ...h 8 The flame intensity can also be displayed by the flame intensity indicator The ECO mode has a modulating effect on flame intensity higher or lower This accentuates the visual effect and user comfort of the flames while reducing the fire s heat emission and gas consumption by approximately 40 Use the remote control to set the flame intensity in ECO mode to 9 after which the double flame icon wi...

Страница 18: ...hese are indicated by switch on times ON 1 2 3 and switch off times OFF 1 2 3 The set programme will run daily 1 Check if the hand transmitter is set at the right time if you are not happy with the time see 4 3 Day and night settings 2 Press the P button hold down briefly 3 Let go of Button P when the time starts to flash in the top left hand corner of the display 4 Press the right button to displ...

Страница 19: ...eplace is burning but also when it is not Potential causes can be Smoking materials in the fireplace especially in the beginning air contamination quality of the type of gas etc Conditions Filth and stains on the glass must be removed immediately Never turn on the fireplace when it has filth or stains on the glass This can lead to permanent contamination Clean the glass after the first use of the ...

Страница 20: ...e smaller than 5 Carefully clean the glass use sufficient moisture avoid pressure and rub the substance from top to bottom to prevent cleaning detergent to remain on the glass Continuously dry the glass completely using the cloth When using a vacuum lifter to remove the door the suction cup rubber must be clean in order to prevent damage to the coating The table below lists the types of products n...

Страница 21: ...teps explained in step 3 in reverse order Lock the door by moving the handles down Twist the metal cover strips step 1 back into its original position by using the protruding lip at the upper side of the strip Install the guard mesh screen See Annex A 3 5 1 3 Door dismantling and assembly corner and three sided appliances Door removal WARNING Wear rubber gloves to prevent stains on the glass Step ...

Страница 22: ...dles down Twist the metal cover strips step 3 back in its original position by using the overlapping edge on the upper side of the strip and fold the metal cover strip down Install the 5 1 4 Door dismantling and assembly front and tunnel fireplaces Door removal WARNING Wear rubber gloves to prevent stains on the glass Step 1 Remove the guard mesh screen See Annex A 3 Step 1 Move the metal cover st...

Страница 23: ... the gas fire The waiting time must be respected also after a power interruption guard mesh screen See Annex A 3 5 2 Malfunctions Malfunctions can be organised in five categories 1 Permanent malfunctions indicated as F This malfunction cannot be fixed automatically the gas fire is blocked for 24 hours except for the error code 02F 2 Recovering malfunctions indicated as ALARM or A Malfunction that ...

Страница 24: ...imulate the synchronisation speed Supply power back to the cable The entire light will start flashing once per second Should the gas fire is provided with a hybrid function and or NSG detach the HCB cable from the automatic burner relay 4 Press on the remote control until NOLK 0 appears on the display Next release 5 In case NOLK 1 or LINK 1 appear press again until NOLK 0 appears 6 Press the black...

Страница 25: ...echnical unit does not flash 1 Check power supply on the mains 230VAC 2 If this is correct check replace the VDC transformer and or automatic burner relay In case the light on the automatic burner relay in the technical unit flashes 1 Place the remote control as close to the fireplace as possible 2 Briefly press and wait approximately 60 seconds 3 Check the transmission strength See Checking trans...

Страница 26: ... burner In case no gas ema nates from the burner check for gas supply up to the technical box measure pre pressure 4 In the presence of pre pressure check whether the cables running from the automatic burner relay to the gas valve unit are damaged and or disconnected 5 In case of an excessive gas pressure level 55mbar the gas valve cannot be opened for safety reasons The energy company or installe...

Страница 27: ...tic burner relay 34F Insufficient voltage 1 Measure mains voltage 220VAC 2 Measure outgoing transformer voltage 24 VDC and 12 VDC 3 If the outgoing voltage is lower than 20 VDC or 10 VDC replace the transformer 4 If the outgoing voltage is correct check the wiring for short circuits 35F Problem with the electrical driver Replace automatic burner relay 50F Gas valve wiring problem Check the wiring ...

Страница 28: ...28 A Appendices A 1 Wiring diagram HDIMS Ionisation AUX enable OPEN enable 24V Ground Stud KF00370 Wiring Diagram Hybrid Shut Down Switch Domotica iMatch Fig 11 Technical box ...

Страница 29: ...veldweg 21 NL 5951 DH Belfeld Certifies that the following Kalfire appliances model gas fire Kalfire G80 48F G85 44C and G90 44S Kalfire G160 41F G165 37C and G170 37S are in compliance with the appliances as described in the AS NZS5601 1 Gas installa tions general installations Date july 2020 Beijko van Melick MSc Managing Director Kalfire BV ...

Страница 30: ...30 A 3 Installing and removing the guard mesh screen Installing the guard mesh screen front models Fig A fireplace with loose guard mesh screen Fig B fireplace with guard mesh screen in place ...

Страница 31: ...the guard mesh screen front models G80 48F and G160 41F Detail guard mesh screen is removed with the help of a guard tool Fig A fireplace with guard mesh screen in place Fig B fireplace with loose guard mesh screen ...

Страница 32: ...32 Installing the guard mesh screen corner and 3 sided models G85 44C G90 44S G165 44C G170 44S Fig A fireplace with loose guard mesh screen Fig B fireplace with guard mesh screen in place ...

Страница 33: ...33 Removing the guard mesh screen corner and 3 sided models G85 44C G90 44S G165 44C G170 44S Fig A fireplace with guard mesh screen in place Fig B fireplace with loose guard mesh screen ...

Страница 34: ...34 ...

Страница 35: ...35 ...

Страница 36: ...Geloërveldweg 21 5951 DH Belfeld info kal fire com KALFIRE COM DON T COMPROMISE REF V03 2021 AU 621015 ...

Отзывы: