11
WARNING
Should the floor in
front of the fireplace consist of
combustible material and the
distance from the underside of the
combustion chamber to the floor
be smaller than 10 cm, a heat-
resistant fireguard floor plate
larger than 30 cm or a stone should
be placed.
Fig. 1:
Safe zone
Danger of combustion
FIRE HAZARD!
Do not touch the
appliance! The gas fire is hot when
switched on or just switched off.
Ensure extra safety precautions
and safety measures if less able-
bodied persons, elderly people
and/or children have access to the
fireplace. Only the remote control
and the technical unit can be used
without fear of danger due to
combustion.
Danger caused by fumes or gas leaks
DANGER OF EXPLOSION!
Fumes
and/or gas leaks can cause life-
threatening situations. Fumes can
be the cause of carbon monoxide
poisoning and gas leaks are an
explosion risk.
If you notice fumes or gas, take the
following precautions:
1.
Switch off the gas fire.
2.
Close the main gas valve.
3.
Open windows and doors.
4.
Advise an approved installer of the
issue.
DANGER OF EXPLOSION!
Should
damage occur, close the gas valve.
Do not use the gas fire if a glass
panel is cracked, is not in place or
incorrectly mounted.
The gas fire needs a permanent power
supply. Interrupting the power supply
can impact safety precautions.
The risk of discolouration
CAREFUL!
After the convection
system of the fireplace has been
heated, air particles, cigarette
smoke, candles and oil lamps
can cause discolouration of walls
and ceilings. Ensure sufficient
ventilation in the room in which the
gas fire is installed.
30 cm
40 cm
100 cm
20°