6. Operation
40
11.
Press or to set the second switch on
time.
12.
Press to confirm this time. The
second temperature setpoint starts
flashing.
13.
Press or to set the second
temperature setpoint.
14.
Press to confirm the second
temperature setpoint. The system will
automatically jump to the next day.
15.
Repeat steps 7 thru 14 for the other six
days.
16.
Press to leave the menu.
Switching off the Fairo
If you are not in the basic menu, press to access the basic
menu. Switch off the Fairo by pressing .
Reset after a malfunction
If the system does not detect any flames
after 30 seconds of sparks or the display
shown appears, then there is a malfunction.
Reset the system by pressing on and
simultaneously. This can be attempted 3x,
afterwards the Fairo will enter malfunction
mode
for 24 hours. For code explanation,
see chapter 8.
1 2 3 4 5 6 7
15:00
II
18.0 C
11
12
13
1 2 3 4 5 6 7
15:00
II
18.0
C
1 2 3 4 5 6 7
15:00
II
22.0
C
14
1 2 3 4 5 6 7
07:00
II
22.0 C
xx
F 13
Reset