Safety instructions
8
DRS30-DRS125
2.2
Signal words in accordance with ANSI
Danger!
Imminent hazard
Consequences of non-observance: serious injury or death
Warning!
Potential hazard
Consequences of non-observance: possible serious injury or death
Caution!
Imminent hazard
Consequences of non-observance: possible injury or property damage
Notice!
Potential hazard
Consequences of non-observance: possible injury or property damage
Important!
Additional advice, info, hints
Consequences of non-observance: disadvantages during operation and maintenance, no danger
2.3
Overview of the safety instructions
Certified skilled personnel
Installation works must exclusively be carried out by authorised and qualified skilled personnel. Prior to
undertaking any measures on the DRS30-DRS125 compressed-air refrigeration dryer, the certified skilled
personnel shall read up on the device by carefully studying the operating instructions. The operator is
responsible for the adherence to these provisions. The respective directives in force apply to the
qualification and expertise of the certified skilled personnel.
For safe operation, the device must only be installed and operated in accordance with the indications in
the operating instructions. In addition, the national and operational statutory provisions and safety
regulations, as well as the accident prevention regulations required for the respective case of application,
need to be observed during employment. This applies accordingly when accessories are used.
Danger!
Compressed air!
Risk of serious injury or death through contact with quickly or suddenly escaping compressed air
or through bursting and/or unsecured plant components.
Compressed air is a highly dangerous energy source.
Never work on the dryer when the system is under pressure.
Never direct the compressed-air outlet or condensate drain hoses at persons.
The user is responsible for the proper installation of the dryer. Non-observance of the instructions in the
"Installation" chapter leads to the expiration of the guarantee. Improper installation may result in
dangerous situations for the personnel and/or the device.
Pos : 5 / Beko Tec hnisc he Dok um ent ati on/Sic herheit/M aß nahmen Dr uckl uft BM @ 0\m od_1184148284291_6.doc @ 5812
Pos : 6 / Beko Tec hnisc he Dok um ent ati on/Sic herheit/ Gefahr N etzs pannung @ 0\mod_1184148186948_6.doc @ 5794
Danger!
Supply voltage!
Contact with non-insulated parts carrying supply voltage involves the risk of an electric shock
resulting in injuries and death.
Only qualified and skilled personnel are authorised to run electrically-operated devices. Prior to
undertaking maintenance measures at the device, the following requirements must be met:
Make sure that the power supply is switched off and that the device is off and marked for maintenance
measures. Please also ensure that the power supply cannot be re-established during the works.
Содержание DRS30
Страница 1: ...Instructions for installation and operation Compressed air refrigeration dryer DRS30 DRS125 EN English...
Страница 19: ...Technical data DRS30 DRS125 19 10 Technical data...
Страница 31: ...Appendices DRS30 DRS125 31 13 Appendices 13 1 Dryer dimensions DRS 30 40...
Страница 32: ...Appendices 32 DRS30 DRS125 13 2 Dryer dimensions DRS 60 80...
Страница 33: ...Appendices DRS30 DRS125 33 13 3 Dryer dimensions DRS 100...
Страница 34: ...Appendices 34 DRS30 DRS125 13 4 Dryer dimensions DRS 125...
Страница 36: ...Appendices 36 DRS30 DRS125 13 5 2 Exploded diagram DRS 30 80...
Страница 37: ...Appendices DRS30 DRS125 37 13 5 3 Exploded diagram DRS 100...
Страница 38: ...Appendices 38 DRS30 DRS125 13 5 4 Exploded diagram DRS 125...
Страница 40: ...Appendices 40 DRS30 DRS125 13 6 2 Electric diagram DRS 30 100...
Страница 41: ...Appendices DRS30 DRS125 41 13 6 3 Electric diagram DRS 125...
Страница 42: ......
Страница 43: ......