Exclusion from a field of application
DRS30-DRS125
11
4
Exclusion from a field of application
Note!
Improper use!
The device is intended for the separation of water in compressed air. The dried air cannot be used for
breathing-air purposes and is not suitable for the direct contact with food.
This dryer is not suitable for the treatment of contaminated air or of air containing solids.
Pos : 16 /Bek o T ec hnis che D ok ument ati on/Bestimm ungsgem äß e Verw endung/ BEKOM AT/ Aus schl uß Anw endung BM 31/ 32/33 @ 0\mod_1236003837511_6.doc @ 13736
5
Operating instructions in accordance with the 2014/68/EU Pressure Equipment Directive
The DRS30-DRS125 compressed-air refrigeration dryer contains pressure equipment in the sense of the 2014/68/EU
Pressure Equipment Directive. Therefore, the entire plant needs to be registered with the supervisory authority if required
in accordance with the local regulations.
For the examination prior to the start-up and for periodic inspections, the national regulations need to be observed, such
as the industrial safety regulation in the Federal Republic of Germany. In countries outside the EU, the respective
regulations in force there need to be adhered to.
The proper use of pressure devices is the basic requirement for safe operation. As regards pressure devices, the
following points need to be observed:
•
The DRS30-DRS125 compressed-air refrigeration dryer must only be employed within the pressure and temperature
range limits indicated by the manufacturer on the name plate.
•
No welding must be carried out on the pressure parts.
•
The DRS30-DRS125 compressed-air refrigeration dryer must neither be installed in insufficiently ventilated rooms
nor near heat sources or inflammable substances.
•
To avoid fractures resulting from material fatigue, the refrigeration dryer should not be exposed to vibrations during
operation.
•
The maximum operating pressure indicated by the manufacturer on the name plate must not be exceeded. It is the
installer's responsibility to install the appropriate safety and control devices. Prior to the start-up of the DRS30-
DRS125 compressed-air refrigeration dryer, the connected pressure generator (compressor etc.) must be set to the
max. permissible operating pressure. The integrated safeguard needs to be checked by an approved inspection
agency.
•
The documents related to the DRS30-DRS125 compressed-air refrigeration dryer (manual, operating instructions,
manufacturer's declaration etc.) must be kept safe for future reference.
•
No objects whatsoever must be installed at or placed on the DRS30-DRS125 compressed-air refrigeration dryer and
the connecting lines.
•
Installation of the plant in frost-free places only.
•
Operation of the plant is only permissible with fully closed and intact housing and cover panels. Operation of the
plant with damaged housing/cover panels is prohibited.
6
Transport
Check the packaging for visible loss or damage. If no visible damage can be ascertained, place the unit in close proximity
to the place of installation and unpack the device.
During this procedure, the dryer must always remain in an upright position. The components may be damaged when the
unit is tilted or turned upside down.
Store the device in a dry environment and do not expose it to extreme weather conditions.
Handle with care. Strong shocks can cause irreparable damage.
Содержание DRS30
Страница 1: ...Instructions for installation and operation Compressed air refrigeration dryer DRS30 DRS125 EN English...
Страница 19: ...Technical data DRS30 DRS125 19 10 Technical data...
Страница 31: ...Appendices DRS30 DRS125 31 13 Appendices 13 1 Dryer dimensions DRS 30 40...
Страница 32: ...Appendices 32 DRS30 DRS125 13 2 Dryer dimensions DRS 60 80...
Страница 33: ...Appendices DRS30 DRS125 33 13 3 Dryer dimensions DRS 100...
Страница 34: ...Appendices 34 DRS30 DRS125 13 4 Dryer dimensions DRS 125...
Страница 36: ...Appendices 36 DRS30 DRS125 13 5 2 Exploded diagram DRS 30 80...
Страница 37: ...Appendices DRS30 DRS125 37 13 5 3 Exploded diagram DRS 100...
Страница 38: ...Appendices 38 DRS30 DRS125 13 5 4 Exploded diagram DRS 125...
Страница 40: ...Appendices 40 DRS30 DRS125 13 6 2 Electric diagram DRS 30 100...
Страница 41: ...Appendices DRS30 DRS125 41 13 6 3 Electric diagram DRS 125...
Страница 42: ......
Страница 43: ......