Kaise KG-300 Скачать руководство пользователя страница 24

High

voltage

0

10

15

kv

s

5

00775

RPM

Higher voltage than other cylinders

Measurement mode

 : Voltage

  ●

Display mode

 : Chart

2nd cylinder shows abnormal voltage when measuring spark plug voltage of 
3-cylinders engine in chart view.

Large

amplitude

0

s

00775

RPM

Large burn time amplitude than other cylinders

Measurement mode

 : Burn Time

  ●

Display mode

 : Chart

3rd cylinder shows abnormal amplitude when measuring spark burn time of 
4-cylinders engine in chart view.

MEASUREMENT EXAMPLES

22

4

6

ms

2

Содержание KG-300

Страница 1: ...IGNITION ANALYZER Instruction Manual KG 300 ...

Страница 2: ...ATION SPECIFICATIONS 1 General Specifications 2 Measurement Specifications MEASUREMENT PROCEDURES 1 Flexible Probe and Sensor Setup 2 Engine Cycle Setting 3 Start Measurement 4 Measurement Mode Setting 5 Display Mode Setting MEASUREMENT EXAMPLES 1 Normal Ignition Coil Waveform 2 Failure Ignition Coil Waveform MAINTENANCE 1 Recharging the Instrument TROUBLE SHOOTING ABOUT KAISE WEBSITE WARRANTY 1 5...

Страница 3: ...ribe the harm and damage that would be caused by incorrect usage Caution marks that require your attention equivalent marks have the same meanings Warnings and cautions that require your attentions Prohibited matters to protect the user and the product Mandatory matters that we ask to comply with WARNING CAUTION This symbol in this manual advises the user of an electrical shock hazard that could r...

Страница 4: ...strument or injury electric shock may occur Detach USB cable after completed the recharging Heat burst fire of the instrument or injury electric shock may occur Stop using the instrument and keep away from fire when there are electrolyte leakage or unusual smell Heat burst fire of the instrument or injury electric shock may occur Do not touch leaking electrolyte If attached to the skin or get into...

Страница 5: ...nsert foreign object Heat burst fire of the instrument or injury electric shock may occur Do not touch sensor and flexible probe when taking measurement Injury or electric shock may occur Do not measure the damaged electric leaked ignition system Heat burst fire of the instrument or injury electric shock may occur Do not use the instrument with wet hands Accident electric shock fire or damage to t...

Страница 6: ...ake long time continuous measurement Heat burst fire of the instrument or injury electric shock may occur 4 Store the instrument in the place less than 45 and 70 humidity Avoid direct sunlight and or inside the sun heated vehicle Heat burst fire of the instrument or injury electric shock may occur Do not attempt to disassemble or modify the instrument Heat burst fire of the instrument or injury el...

Страница 7: ... burst fire of the instrument or injury electric shock may occur Do not put the instrument in microwave or high pressure container Heat burst fire of the instrument or injury electric shock may occur Keep away the pet animals from the instrument Heat burst fire of the instrument or injury electric shock may occur Do not charge the instrument when it is full charged Heat burst fire of the instrumen...

Страница 8: ...ables could cause dangerous short circuit Stop using the instrument and ask your local dealer for test lead replacement Keep away from high electromagnetic environment Damage to the instrument may occur Recharge the instrument every 2 months when the instrument is out of use for a long time Internal lithium battery could be damaged significantly depending on the usage or storage conditions Failure...

Страница 9: ...good condition If there are any damages or missing ask your local dealer for replacement Main Unit 1 pc Holster 1 pc attached 672 High Tension Cord Sensor 1 pc 670 Flexible Probe 1 pc 671 Direct Ignition Sensor 1 pc 933 USB Cable 1 pc 1029 Carrying Case 1 pc 7 IGNITION ANALYZER KG 300 Instruction Manual 1 pc ...

Страница 10: ...70 flexible probe LCD Display POWER CLEAR Key Press this key to turn ON the instrument Press and hold this key for 3 seconds or more to turn OFF the instrument When the instrument is ON press this key to clear all measurement data and start a new measurement CYCLE Key Press this key to open a pull down menu to select the number of strokes corresponding to the engine under measurement 8 ...

Страница 11: ...ted Press this key again to resume normal operation When in the comparison display mode use this key to start and stop a measurement MODE Key Press this key to open a pull down menu to select the type of measurement VIEW Key Press this key to open a pull down menu to select how the chosen measurement will be shown in the display 9 ...

Страница 12: ...s the selected type of measurement see page 15 Display Mode This icon shows the selected display mode see page 16 Tachometer Reading Digital readout of the engine RPM Battery Level Indicator This icon shows the state of charge of the internal battery Measurement Display Area Current measurement is displayed corresponding to the selected display mode 10 Full Empty ...

Страница 13: ...thout probe 670 Flexible Probe 671 Direct Ignition Sensor 672 High Tension Cord Sensor 933 USB Cable Instruction Manual 1029 Carrying Case SPECIFICATIONS LCD Display Frame Rate Power internal Battery Life USB Connector input Auto Power Off Ignition System Engine Cycle OperationTemp Humid StorageTemp Humid Altitude Safety Level Flexible Probe Length Dimensions Weight Accessories 1 2 3 4 5 6 7 8 9 1...

Страница 14: ... WARNINGS and CAUTIONS in pages 1 to 6 Insert the appropriate sensor to the probe tip Dial Connect the probe to the instrument using their BNC connectors Turn the dial until locked BNC connector Probe tip Direct Ignition High Tension Cord High tension cord sensor Direct ignition sensor Probe tip CLEAR HOLD MODE CYCLE VIEW IGNITION ANALYZER KG 300 ...

Страница 15: ...E Key Pull down menu will open with the current setting highlighted Press CYCLE Key repeatedly until the correct setting is highlighted Wait until the pull down menu closes The new setting is displayed on the screen 2 stroke engine cycle 4 stroke engine cycle Waste spark ignition system 5 4 2 0 2 ms 0 01607RPM 4 Stroke 2 Stroke Waste Spark Engine cycle selection menu 13 ...

Страница 16: ...t measurement is displayed on the screen Measuring with High Tension Cords Place the high tension cord into the slot of the sensor If the tachometer reading is unstable reposition the sensor as far as possible from other high tension cords Measuring Direct Ignition System Place the sensor on the top and center of the ignition module Reposition the sensor if the instrument is unable to detect the s...

Страница 17: ...setting is displayed on the screen BurnTime FiringTime Measuring the period from a spark is started to extinguished Misfire might be occur even when burn time is measured RampTime Dwell when using high tension code sensor Measuring the period from primary coil current first begins to increase to when it stops increasing Voltage Measuring spark plug voltages Secondary firing voltage level to compar...

Страница 18: ...ul to compare the sets of minimum average and maximum values between several cylinders Chart i e trend line view Displays the measurement value as the time series chart This view is useful to check the variability over time Digital view This view provides digital and analog readouts for the selected measurement as well as the other two digital readouts Waveform i e oscilloscope view This view disp...

Страница 19: ...asurement mode HOLD Key Press to hold the display in its current condition Press again to resume normal measurement When displaying Tachometer measurement scale vertical axis just shows the first digit of the RPM Read the scale with thousandfold e g RPM measurement scale is 2 2000 RPM actually Measurement scale Time Old New corresponding to each of the last 276 sparks 0 S 2 3 RPM 1 01607RPM ...

Страница 20: ...the display in its current condition HOLD appears on the screen Press again to restart the measurement and add a new graph at the right of the screen POWER CLEAR Key Press to clear all values in the chart MODE Key Press to change the measurement mode When comparing the cylinders place the sensor on the same position of each ignition module and in the same way Average Oldest graph Newest graph Maxi...

Страница 21: ...readouts POWER CLEAR Key Press to re scale the analog meter gauge MODE Key Press to change the measurement mode HOLD Key Press to hold the display in its current condition Press again to resume normal measurement Software version of this instrument is displayed at the top of the screen when Tachometer measurement mode is selected Selected measurement readout Analogmeter oftheselected measurement O...

Страница 22: ...Key Press to hold the display in its current condition Press again to resume normal measurement Waveform related to the selected measurement mode is displayed on the screen To display the whole image select Voltage or Tachometer measurement mode When the waveform is bigger than the present scale press POWER CLEAR Key to re scale the time and signal level axes Signal level Time 10 10 20 kv 4 2 0 2 ...

Страница 23: ... Spark line Decay Primary coil point Close 5 5 10 kv 4 2 0 2 ms 0 01377RPM High peak voltage Primary coil point Open Measurement mode Voltage Display mode Waveform 2 Failure Ignition Coil Waveforms High peak voltage Measurement mode Voltage Display mode Waveform 15 15 30 kv 8 4 0 4 ms 0 01833RPM ...

Страница 24: ...rmal voltage when measuring spark plug voltage of 3 cylinders engine in chart view Large amplitude 0 s 00775RPM Large burn time amplitude than other cylinders Measurement mode Burn Time Display mode Chart 3rd cylinder shows abnormal amplitude when measuring spark burn time of 4 cylinders engine in chart view MEASUREMENT EXAMPLES 22 4 6 ms 2 ...

Страница 25: ...n Time Display mode Comparison MEASUREMENT EXAMPLES 23 0 4 6 ms s 2 00753RPM High average value Large amplitude Large maximum to minimum range with high voltage value Measurement mode Voltage Display mode Comparison 0 10 15 kv s 5 00753RPM High average value Large amplitude ...

Страница 26: ... cap located besides the BNC connector Insert the micro USB plug of 933 USB Cable firmly into the receptacle of the instrument WARNING CAUTION To avoid any injuries and damage to the instrument strictly observe the WARNINGS and CAUTIONS in pages 1 to 6 Micro USB connector cap Micro USB plug USB power adapter Rated voltage 5V Rated current 1A or more 933 USB Cable USB type A connector USB power ada...

Страница 27: ...reen will turn off after a few seconds Press POWER CLEAR Key to turn on again Measurement or other operation are prohibited while charging Upon the battery is fully charged the display will show the charging complete icon Press POWER CLEAR Key to confirm the icon Unplug the power adapter and disconnect the cables Charging in progress 25 Charging complete ...

Страница 28: ...attery See page 24 Problem Possible Cause Suggested Correction Cannot turn on Loose connection of flexible probe or sensor Be sure to insert all the way Sensor position is inappropriate Reposition the sensor No ignition signal detected High tension cords are crowded Separate the high tension cords as far as possible Sensor position is inappropriate Reposition the sensor Measurement is unstable Loo...

Страница 29: ...ABOUT KAISE WEBSITE 27 Visit our website for more products information 1 Kaise Corporation Website https www kaise com 2 KG 300 Product Page URL https www kaise com e_car_kg300 html ...

Страница 30: ... transport charges prepaid KAISE AUTHORIZED DEALER and the manufacturer KAISE CORPORATION shall not be liable for any consequential damages loss or otherwise The foregoing warranty is exclusive and in lieu of all other warranties including any warranty of merchantability whether expressed or implied This warranty shall not apply to any instrument or other article of equipment which shall have been...

Страница 31: ...ZED DEALER 422 Hayashinogo Ueda City Nagano Pref 386 0156 Japan TEL 81 268 35 1601 FAX 81 268 35 1603 E mail sales kaise com http www kaise com Product specifications and appearance are subject to change without notice due to continual improvements ...

Отзывы: