” when Wireless Control feature is activated(some units)
“
”
Displays temperature, operation feature and Error codes:
“ ” for 3 seconds when:
• TIMER ON is set
• FRESH, SWING, TURBO, SILENCE or SOLAR PV ECO feature is turned on
NOTE: Different models have different front panel and display window. Not all the indicators
describing below are available for the air conditioner you purchased. Please check the indoor display
window of the unit you purchased.
Illustrations in this manual are for explanatory purposes. The actual shape of your indoor unit
may be slightly different. The actual shape shall prevail.
” for 3 seconds when:
“
• TIMER OFF is set
• FRESH, SWING, TURBO, SILENCE or SOLAR PV ECO feature is turned off
” when anti-cold air feature is turned on
” when defrosting(cooling & heating units)
” when unit is self-cleaning
” when 8 C heating feature is turned on
“
“
“
“
“
Power Cable (Some Units)
Remote Control
Remote Control
Holder (Some Units)
Louver
Front Panel
Air Filter
(pull out)
Display window
Display Code
Meanings
illuminates gradually one by one as
,
,
When ECO function(some units) is activated, the
set temperature -- ...... in one second interval.
Unit Specifications and Features
Indoor unit display
-- -- --
Room
Temperature
17°-32°C (63°-90°F)
0°-30°C (32°-86°F)
10°-32°C (50°-90°F)
Outdoor
Temperature
18°-43°C (64°-109°F)
-7°-24°C (19°-75°F)
11°-43°C (52°-109°F)
18°-43°C (64°-109°F)
-7°-43°C (19°-109°F)
(For models with low-temp cooling systems)
18°-52°C (64°-126°F)
(For special tropical models)
18°-52°C (64°-126°F)
(For special tropical models)
Cool mode
Heat mode
DRY mode
Cool mode
Heat mode
DRY mode
Room Temperature
17°C - 32°C
(63°F - 90°F)
0°C - 30°C
(32°F - 86°F)
10°C - 32°C
(50°F - 90°F)
Outdoor
Temperature
0°C - 50°C
(32°F - 122°F)
0°C - 50°C
(32°F - 122°F)
(For models with
-15°C - 50°C
(5°F - 122°F)
low temp. cooling
systems)
0°C - 52°C
(32°F - 126°F)
(For special
tropical models)
0°C - 52°C
(32°F - 126°F)
(For special
tropical models)
FeaturesAchieving Optimal Performance
Typ inwerterowy
Typ o stałej częstotliwości
-25°C - 30°C
(-13°F - 86°F)
NOTE:
Room relative humidity less than 80%. If the air conditioner operates in excess of this figure, the surface
of the air conditioner may attract condensation. Please sets the vertical air flow louver to its maximum
angle (vertically to the floor), and set HIGH fan mode.
Optimal performance for the COOL, HEAT, and DRY modes can be achieved in the following temperature
ranges. When your air conditioner is used outside of these ranges, certain safety protection features will
activate and cause the unit to perform less than optimally.
When outside temperature
is below 0°C (32°F ), we
strongly recommend
keeping theunit plugged
in at all time to ensure
smoothongoing
performance.
FOR OUTDOOR UNITS
WITH AUXILIARY
ELECTRIC HEATER
To further optimize the performance of your unit, do the following:
• Keep doors and windows closed.
• Limit energy usage by using TIMER ON and TIMER OFF functions.
• Do not block air inlets or outlets.