43
3. The list of parameters for the zone control function will be displayed.
13.7.2. Degrees of the mixing valve
In heating mode:
The device will adjust the degrees of the mixing valve automatically. There is no need to set them
manually.
13.8. Parameters
Note:
S –means temperature sensor
T –means thermostat
P –means passive thermostat
RT –means room temperature
WT –means water temperature
Code
Parameter
Range
Z01
Activate zone control.
1- Zone 1-S
2- Zone 2-S
3- Zone 1&2-S
4- Zone 1-T
5- Zone 2-T
6- Zone 1&2-T
7- Zone 1-P
8- Zone 2-P
9- Zone 1&2-P
Z02
Target room temperature for Zone 1.
10-35 °C
Z03
Temperature difference for Zone 1 to start operation.
0-10 °C