13.2.3. The Zone Control Interface:
Click „
” to access the Zone Control Interface:
1
When Z16=0(Disable weather compensation curve in zone 1), display Z06
(Target outlet temperature in zone 1);
When Z16=1(Enable weather compensation curve in zone 1), display target
outlet water temperature after compensation.
2
Z02 - Room target temperature in zone 1.
3
When Z17=0(Disable weather compensation curve in zone 2), display Z07
(Target outlet temperature in zone 2);
When Z17=1(Enable weather compensation curve in zone 2), display target
outlet water temperature after compensation.
4
Z03 - Room target temperature in room 2,
5
This arrow is displayed when the heating mode is running.
6
This arrow is displayed when running hot water mode,
high temperature disinfection mode.
7
Display outlet water temperature T02,
when the water temperature sensor has fault, display -.- °C/°F.