NOTE:
The minimum distance between the
outdoor unit and walls described in the
installation guide does not apply to airtight
rooms. Be sure to keep the unit unobstructed
in at least two of the three directions (M, N, P)
(See Fig. 9.5)
Fig. 9.5
Outdoor Unit Mounting Dimensions
Rows of series installation
L
≤
H
L
≤
1/2H
L
A
25 cm / 9.8” or more
1/2H < L
≤
H
30 cm / 11.8” or more
L
>
H
Can not be installed
The relations between H, A and L
are as follows.
B
A
D
The mounting dimensions vary among different outdoor units.
The fixing bolt head diameter should be more than 12mm.
Outdoor Unit Dimentsion (mm)
Mounting Dimentsion (mm)
W
H
D
A
B
952
1333
415
634
404
900
1170
350
590
378
Fig. 9.3
M
N
P
30 cm / 12” from back wall
60 cm / 24” above
30 cm / 12” on left
30 cm / 12”on right
200 cm / 79” in front
W
H
Outdoor Unit
Installation
Outdoor Unit Dimentsion (mm)
Mounting Dimentsion (mm)
W
H
D
A
B
681
434
285
460
292
700
550
275
450
260
300
333
363
420
555
554
702
810
770
800
845
946
487
514
540
673
298
340
350
403
Fig. 9.4
W
H
A
B
D
93