Wiring

 Page 33

 

 

 

 BEFORE PERFORMING ANY 

 ELECTRICAL WORK, READ THESE 

 REGULATIONS 

1. All wiring must comply with local and national 

    electrical codes, regulations and must be 

    installed by a licensed electrician.

2. All electrical connections must be made 

    according to the Electrical Connection Diagram

    located on the panels of the indoor and outdoor 

    units. 

3. If there is a serious safety issue with the power 

    supply, stop work immediately. Explain your

    reasoning to the client, and refuse to install the 

    unit until the safety issue is properly resolved.

4. Power voltage should be within 90-110% of 

    rated voltage. Insufficient power supply can

    cause malfunction, electrical shock, or fire. 

5. If connecting power to fixed wiring, a 

    surgeprotector and main power switch should 

    be installed.

6. If connecting power to fixed wiring, a switch 

    or circuit breaker that disconnects all poles and 

    has a contact separation of at least 1/8in (3mm) 

    must be incorporated in the fixed wiring. The 

    qualified technician must use an approved 

    circuit breaker or switch.    

13. 

Make sure that you do not cross your

       electrical wiring with your signal wiring.

       This may cause distortion and 

       interference.

14. 

The unit must be connected to the 

       main outlet. Normally, the power supply 

       must have a impedance of 32 ohms.

15. 

No other equipment should be 

       connected to the same power circuit.

16. 

Connect the outdoor wires before 

       connecting the indoor wires.

7. Only connect the unit to an individual branch 

    circuit outlet. Do not connect another 

    appliance to that outlet.   

8. Make sure to properly ground the air conditioner.

9. Every wire must be firmly connected. Loose 

    wiring can cause the terminal to overheat, 

    resulting in product malfunction and possible fire.

    Do not let wires touch or rest against refrigerant 

    tubing, the compressor, or any moving parts 

    within the unit.  

    If the unit has an auxiliary electric heater, it must

    be installed at least 1 meter (40in) away from 

    any combustible materials. 

    To avoid getting an electric shock, never touch 

    the electrical components soon after the power 

    supply has been turned off. After turning off 

    the power, always wait 10 minutes or more 

    before you touch the electrical components.  

    

10. 

11. 

12. 

 WARNING

BEFORE PERFORMING ANY 

ELECTRICAL OR WIRING WORK, 

TURN OFF THE MAIN POWER TO 

THE SYSTEM. 

 

 

 

 

Wiring

Indoor unit

Outdoor unit

Air switch

(purchased seperately)

(purchased seperately)

Outdoor unit power wires

Indoor & Outdoor 

connective  wires

(A)

NOTE ON  AIR SWITCH

When the maximum current of  the air 

conditioner is more than 16A, an air switch or 

leakage protection switch with protective 

device shall be used(purchased seperately) . 

When the maximum current of  the air 

conditioner is less than 16A, the power cord 

of air conditioner shall be equipped with 

plug (purchased seperately) .

In North America

the applicance should be 

wired according to NEC and CEC requirements.

Содержание KFAU-12HRG32X

Страница 1: ...before installing or operating your new air conditioning unit Make sure to save this manual for future reference Please check the applicable models technical data F GAS if any and manufacturer inform...

Страница 2: ......

Страница 3: ...Drill wall hole for connective piping 6 Connect drain hose Outdoor Unit Installation 1 Select installation location 2 Install drain joint Wiring 1 Outdoor Uint Wiring 3 Power Specifications 3 Anchor o...

Страница 4: ...mell immediately turn off the unit and disconnect the power Call your dealer for instructions to avoid electric shock fire or injury Do not insert fingers rods or other objects into the air inlet or o...

Страница 5: ...nsion cord to power the unit Do not share the electrical outlet with other appliances Improper or insufficient power supply can cause fire or electrical shock If connecting power to fixed wiring an al...

Страница 6: ...install the appliance to its support please read the information for details in indoor unit installation and outdoor unit installation sections For units that have an auxiliary electric heater do not...

Страница 7: ...usable mechanical connectors and flared joints are not allowed indoors EN Standard Requirements Mechanical connectors used indoors shall have a rate of not more than 3g year at 25 of the maximum allow...

Страница 8: ...n buying a new appliance the retailer will take back the old appliance free of charge The manufacturer will take back the old appliance free of charge Sell the appliance to certified scrap metal deale...

Страница 9: ...ies Drain hose Refrigerant connecting pipe Display panel Air inlet with air filter in it Air flow louver at air outlet Air flow louver at air outlet Display panel Displays temperature and Error codes...

Страница 10: ...erature 16 C 32 C 60 F 90 F 0 C 30 C 32 F 86 F 10 C 32 C 50 F 90 F Outdoor Temperature 18 C 43 C 64 F 109 F 7 C 24 C 19 F 75 F 11 C 43 C 52 F 109 F 7 C 43 C 19 F 109 F For models with low temp cooling...

Страница 11: ...restart using the same settings Louver Angle Memory Function some models Some models are designed with a louver angle memory function When the unit restarts after a power failure the angle of the hor...

Страница 12: ...the switch status of the lower air louver on open of closed Page 12 Unit Specifications and Features Adjusting Air Flow Direction CAUTION Do not try to adjust the horizontal louver by hand This may ca...

Страница 13: ...to clean the filter once every two weeks WARNING DO NOT REMOVE OR CLEAN THE FILTER BY YOURSELF Removing and cleaning the filter can be dangerous Removal and maintenance must be performed by a certifie...

Страница 14: ...uthorized dealer or a licensed service provider Any unit repairs should be performed by an authorized dealer or a licensed service provider Maintenance Pre Season Inspection After long periods of non...

Страница 15: ...due to expansion and contraction of the unit s plastic parts Both the indoor unit and outdoor unit make noises Low hissing sound during operation This is normal and is caused by refrigerant gas flowin...

Страница 16: ...detailed description of the unit malfunction as well as your model number Troubleshooting When troubles occur please check the following points before contacting a repair company Problem Possible Caus...

Страница 17: ...mely low Use auxiliary heating device Cold air is entering through doors and windows Make sure that all doors and windows are closed during use Low refrigerant due to leak or long term use Check for l...

Страница 18: ...dels 2 1 Red short connected wire some models Air freshening filter some models The air conditioning system comes with the following accessories Use all of the installation parts and accessories to in...

Страница 19: ...Install the outdoor unit 1 2 3 4 5 MC MC 6 7 Install the indoor unit Evacuate the refrigeration system Connect the wires Connect the refrigerant pipes Perform a test run Page 19 Installation Summary...

Страница 20: ...accordance with the requirement of local and national standards The installation may be slightly different in different areas Unit Parts Display panel Drain pipe Connecting pipe Air inlet Air outlet A...

Страница 21: ...h room exists for installation and maintenance Enough room exists for the connecting the pipe and drainpipe The ceiling is horizontal and its structure can sustain the weight of the indoor unit The ai...

Страница 22: ...installed horizontally NOTE If the pipe comes out on the left it is necessary to loosen the screws on the bottom mounting plate If the pipe comes out in other directions it is not necessary Mounting p...

Страница 23: ...ounting plate installation Installation without skirting Installation with skirting line Knock the bottom mounting plate straight with a tool and fix it on the skirting line Two buckles The bottom mou...

Страница 24: ...and other sensitive Wall Indoor Outdoor 12mm 0 5 inch 2 Remove the cover plate NOTE All the figures in this manual are for demonstration purposes only The air conditioner you have purchased may be sli...

Страница 25: ...el switch malfunction In HEAT mode the outdoor unit will discharge water Ensure that the drain hose is placed in an appropriate area to avoid water damage and slippage DO NOT pull the drainpipe forcef...

Страница 26: ...ir outlet fan is at a 90 angle to the direction of the wind If needed build a barrier in front of the unit to protect it from extremely heavy winds See Figures below Strong wind Strong wind Strong win...

Страница 27: ...ee Fig B do the following 1 Insert the drain joint into the hole in the base pan of the unit The drain joint will click in place 2 Connect a drain hose extension not included to the drain joint to red...

Страница 28: ...6 14 673 26 5 403 15 87 952x1333x410 37 5x52 5x16 14 634 24 96 404 15 9 890x673x342 35x26 5x13 46 663 26 1 354 13 94 952x1333x415 37 5x52 5x16 34 634 24 96 404 15 9 845x702x363 33 27x27 6x14 3 540 21...

Страница 29: ...s meets the requirements shown in the following table The Maximum Length And Drop Height Based on Models Unit m ft Type of model Capacity Btu h Length of piping Maximum drop height North America Austr...

Страница 30: ...arped 90 DO NOT DEFORM PIPE WHILE CUTTING Be extra careful not to damage dent or deform the pipe while cutting This will drastically reduce the heating efficiency of the unit Step 2 Remove burrs Burrs...

Страница 31: ...Flare the pipe in accordance with the dimensions PIPING EXTENSION BEYOND FLARE FORM 8 Remove the flaring tool and flare form then inspect the end of the pipe for cracks and even flaring Step 4 Connect...

Страница 32: ...m 3 9 6 After connecting the copper pipes to the indoor unit wrap the power cable signal cable and the piping together with binding tape NOTE DO NOT intertwine signal cable with other wires While bund...

Страница 33: ...o the same power circuit 16 Connect the outdoor wires before connecting the indoor wires 7 Only connect the unit to an individual branch circuit outlet Do not connect another appliance to that outlet...

Страница 34: ...ased seperately purchased seperately Indoor unit power wires Indoor Outdoor connective wires Outdoor unit power wires C NOTE The cographs are for explanation purpose only Your machine may be slightly...

Страница 35: ...es 2 Pull the left and right handles of the front panel pull the panel outward and open the panel Magnetic ring if supplied and packed with the accessories Pass the belt through the hole of the Magnet...

Страница 36: ...FUSE A INDOOR UNIT POWER WIRING mm OUTDOOR UNIT POWER WIRING GROUND WIRING STRONG ELECTRIC SIGNAL WEAK ELECTRIC SIGNAL INDOOR OUDOOR CONNECTING WIRING mm 16K 1 Phase 220 240V 50Hz 60Hz 20 16 3x1 5 4x...

Страница 37: ...nutes or until the Compound Meter reads 76cmHG 105 Pa 2 3 4 5 6 Close the Low Pressure side of the manifold gauge and turn off the vacuum pump 7 Wait for 5 minutes then check that there has been no ch...

Страница 38: ...ndard pipe length x60g 0 64oZ m ft Total pipe length standard pipe length x65g 0 69oZ m ft R410A orifice tube in the indoor unit Total pipe length standard pipe length x30g 0 32oZ m ft Total pipe leng...

Страница 39: ...ectly d Ensure the indicators on the remote control and the display panel on the indoor unit work properly e Ensure the manual buttons on the indoor unit works properly f Check to see that the drainag...

Страница 40: ...fications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the service website...

Отзывы: