6
Kaden Owner’s Guide
Evaporative Air Coolers
INTRODUCTION
Congratulations on your purchase of a Kaden Cooling system. For you to achieve the performance and efficiency
expected from your new cooler, please ensure the installer is a qualified trades person, that the installer has
commissioned the unit before you commence operating, and you take the time to read the contents of this manual�
In some Australian States it is mandatory that your cooler installation is issued with a certificate of compliance
to guarantee the installation workmanship� Please check with your installer or the local plumbing authority or
association� The Kaden cooler is covered by the product warranty as outlined in this manual�
HOW DOES YOUR EVAPORATIVE COOLER WORK?
The amount of cooling available from any type of cooling system is dependent on the outside weather conditions�
Your evaporative cooler works best on hot, dry days� It is essential to provide the required amount of ventilation (for
your evaporative cooling system to function properly) by opening windows/doors whenever the cooler is operating�
Air is drawn in through the filter pads resulting in 100% fresh cool air entering the home. The movement of this
cooled air through your home will draw the heat out of the house, so be sure that doors or windows are open to
expel this heat to outside.
Whenever possible start the cooler early to prevent the build up of heat within the house, and on sultry or humid
days your cooler may work better with the fan
ONLY
running and the pump turned OFF� Stale air, cigarette smoke
and fumes can be quickly cleared and replaced with fresh air by turning the fan to manual mode�
BEFORE OPERATING YOUR EVAPORATIVE COOLER
Make sure enough window and/or door area is open for the unit to work correctly� The following table gives a guide
to the amount of open area required for each model in m
2
, and also gives suggestions on how to provide this�
Model
Number of average size windows & doors
(suggestive only)
Highest
Fan
Setting
Lowest
Fan
Setting
Low Profile Classic
KL16
KC17
Two sliding windows or Five hinged windows
1�5 m
2
0�9 m
2
KL22
-
One door and a hinged window
1�9 m
2
1�1 m
2
KL25
KC21
Three sliding windows or one door & two hinged windows
2�3 m
2
1�4 m
2
-
KC27
Four sliding windows or one door and four hinged windows
2�8 m
2
1�7 m
2
KL28
-
Five sliding windows or one door and five hinged windows
3�1 m
2
1�9 m
2
-
KC32
Six sliding windows or one door and six hinged windows
3�4 m
2
2�1 m
2
Door = 1.6m²
Hinged Window = 0.3m²
Sliding Window = 0.7m²
Average ventilation area provided by various openings when fully opened�
NOTE
You can also choose to have these openings only halfway open, however note that the opening
will only provide half the amount of ventilation shown above and additional ventilation openings
would be required.
EVAPORATIVE COOLER OPERATION