M a i n t e n a n c e / T r o u b l e s h o o t i n g
Page 48
Installation Instructions blueplanet XP10U H4 / H6 and XP10U H4 / H6 PSD
Status
Display
Explanation
Action
By
FS
67
Fault power
section 1
There is a fault in the power section.
Notify your autho-
rised electrician.
E
FS
70
Fan error
Fan 1 is malfunctioning.
Replace defective
fan
E
FS
73
Standalone
grid err.
Standalone mode was detected.
-
-
OS
74
External
idle power
requirement
The grid operator limits the feed-in power
of the inverter.
-
-
Table 6:
Operating states and fault messages on the display
OS = operating status, FS = fault status;
O = Action of the operator
E = The indicated work must only be carried out by an authorised electrician.
K = The indicated work must only be carried out by a service employee of KACO new energy, Inc
.