13  Mounting the locking system 

 
Following the mounting preparation, the actual mounting of the lock (1) and of the input unit (8 + 11) can take place. 
 

13.1 

Mounting the lock 

 
The  lock  (1)  must  be  mounted  in  the  secure  storage  unit  as  follows:  The  lock  (1)  must  be  mounted  while  locked  (with  the 
exception  of  the  bolt).  Do not apply  any  force  (e.g.,  hammer  blows)  when  screw-connecting  and adjusting  the  lock and  make 
sure that the bolt can be freely moved in the installed position. The lock must be installed protected against drilling and covered, 
if necessary. Use steel cheese head screws M 6 or steel inch screws BSW ¼“. The length must be selected, taking into account 
the  screw  connection  height  of  the  lock  of  24  mm  plus  the  required  screwing  depth  according  to  current  standards.  A  thread 
length of at least 30 mm is recommended. For the fastening screws, a minimum strength class of 4.8 and a maximum strength 
class of 8.8 must be observed. The screws must be secured either with a spring washer, toothed lock washer or serrated lock 
washer or by means of a screw-locking adhesive. The tightening torque must be between 5 and 6 Nm.  
After mounting and adjusting the lock on the storage unit door, you must ensure that the key can be inserted without tilting and 
without applying force. 
 

13.2 

Mounting the drive shaft 

 
Insert the  O-ring  (3) on  the  side  of  the  optionally  shortened  drive  shaft  that  was  not drilled  (see  12.3)  over  a  length  of 5  mm,  
but not more than 8 mm (see Figure 34). 
 
 
 
 
 
 
 
 
 
 
 

Figure 34: Mounting the O-ring 

 
 

NOTICE

: Under no circumstances should the O-ring be inserted over a length of more than 8 mm! Faultless functioning 

of the lock can only be insured if the O-ring is positioned correctly! 
 

Next, the drive shaft (2) is inserted into the lock with its drilled side pointing forward (see Figure 34) as far as it will go.

 

 

 

 

Insert drilled side into 
the lock 

approx. 5mm 

Maximum: 8 mm 

Содержание Combi B 30 Series

Страница 1: ...metal input unit Mounting instructions EN CLAVIS Deutschland GmbH Schillerstraße 47 51 34117 Kassel Telefon 49 0 561 988 499 0 Fax 49 0 561 988 499 99 E Mail info tresore eu Internet www tresore eu www tresorschloss de ...

Страница 2: ...t 30 12 3 Drive shaft 31 13 Mounting the locking system 32 13 1 Mounting the lock 32 13 2 Mounting the drive shaft 32 13 3 Mounting the input unit 33 13 3 1 Dismounting the input unit 33 13 3 2 Adjusting the keypad sub assembly 34 13 3 3 Mounting the connecting cable 36 13 3 4 Fastening the base part 37 13 3 5 Inserting the batteries 37 13 3 6 Mounting the input unit top part 38 13 4 Checking perf...

Страница 3: ...to the upper part of the keypad frame 34 Figure 40 After removing the top holder turn around the fitting 34 Figure 41 Carefully pull out the keypad sub assembly toward the back 34 Figure 42 Mounting the keypad sub assembly 35 Figure 43 Connecting cable from the input unit to the lock 36 Figure 44 Detail of the socket 36 Figure 45 Inserting the top part 38 Figure 46 Moving the top part 38 Figure 47...

Страница 4: ...k the locking system must be de energized during wiring i e the batteries in the input unit and power supply units must be removed Otherwise the lock electronics may become damaged The locking system is suitable for installation in secure storage units made of steel provided with or devoid of padding materials Installation in units made of other materials such as plastic is not allowed The proper ...

Страница 5: ...ion switch Change over contact 30V DC 0 1 A Pin1 Common Pin2 Normally Closed Pin3 Normally Open Silent alarm 3 Max 24 V DC 25 mA Pin6 Collector Pin7 Emitter Lock Input signal Only configurable via the Combi B 30 configuration software only one function each possible stan dard disabled Remote control disable 12V DC 10 Pin4 12V Pin5 GND Omission alarm min actuation time 500 ms opening must take plac...

Страница 6: ...o lock 6 pin connector I O mini USB connector Data interface to PC Connects the input unit to the PC by means of the Kaba Mauer CB30 PC cable in order to read the audit or configure the lock As pre assigned internally Notice Special interface use only original Kaba Mauer CB30 PC cable Table 8 Overview input unit connections Figure 26 Input unit connection I O mini USB connector Connecting cable to...

Страница 7: ...crew for arresting the upper part of the input unit F H 2 9 x 6 5 mm 7 Rotary handle 8 Upper part of the input unit 9 Mounting screws for base part M4 x 6 0 mm 10 Cable binder 11 Base part of the input unit 12 Connecting cable input unit lock Not included in the scope of delivery 13 Mounting screws for the lock recommended M6 x 30 mm or x 30 mm see chapter 13 1 14 2 batteries 1 5 volts type AAA LR...

Страница 8: ...ons that are outside the data shown in Figure 28 must be coordinated separately with certifiers test institutes The position of the key hole the dimensions and the resulting required space for the installation of the lock can be seen from Figure 28 The following figure refers to the installation position Bolt on the left For other installation positions the figure must be rotated according to Tabl...

Страница 9: ...secure storage unit it is recommended inserting the Kaba Mauer key guide see Figure 29 or the Kaba Mauer key carrier guide see Figure 30 In these cases taking into consideration DIN 2768 mH the key in the secure storage unit must be manufactured with the corresponding dimensions Figure 29 Key guide 86101 Figure 30 Key carrier guide R 4 R4 O 8 4 2 4 2 5 9 5 9 25 5 1 2 75 ...

Страница 10: ...Table 11 if necessary In addition to that another cutout is required in the cabinet door used as cable passage for the connecting cable 12 between lock 1 and input unit 8 11 The size of the cable passage hole must not be more than 100 mm 2 e g a hole max 11 25 in diameter and the hole must be positioned within the area of Figures 32 Installation position Figure Rotation 32 Not required 32 90 clock...

Страница 11: ...ween the lock mounting plane and the input unit mounting plane 20 mm immersion depth into the input unit 26 5 mm immersion depth into the lock tolerance 0 2 mm see Figure 32 Shorten the drive shaft 2 only on the side not drilled see Figure 33 To shorten it the drive shaft 2 must be removed from the lock since otherwise there will be a risk of damaging the lock Figure 32 Required length of the driv...

Страница 12: ...t 30 mm is recommended For the fastening screws a minimum strength class of 4 8 and a maximum strength class of 8 8 must be observed The screws must be secured either with a spring washer toothed lock washer or serrated lock washer or by means of a screw locking adhesive The tightening torque must be between 5 and 6 Nm After mounting and adjusting the lock on the storage unit door you must ensure ...

Страница 13: ...len wrench Insert Allen wrench 5 as shown in the figure into the small hole in the input unit 8 11 as far as it will go Figure 36 Pulling off the rotary handle Keep the Allen wrench 5 pressed while pulling off the rotary handle 7 toward the front as shown Figure 37 Loosening the screw Move the top part of the input unit 8 in the direction of the arrow until it makes contact with the base part 11 F...

Страница 14: ...b assembly from its top holders Next remove the keypad unit carefully from its bottom holders see Figures 42 and 43 and then take it out of the top part of the operating unit 8 toward the back if possible without tilting or deforming the holding clamps Remark Do not mount the keypad sub assembly in other top parts because the top parts of the input unit 8 is labled with the product data label with...

Страница 15: ...ry handle on the left keypad on the right Not required Rotary handle at the top keypad at the bottom 90 counterclockwise Rotary handle at the bottom keypad at the top 90 clockwise Rotary handle on the right keypad on the left 180 Table 12 Installation position of the input unit notes for Figures15 to18 Figure 42 Mounting the keypad sub assembly ...

Страница 16: ...art 11 via the green miniplug JST 5 pin see Figure 43 step I Notice In doing so ensure correct alignment of the plug to the socket Under no circumstances must the plug be inserted twisted and with force since the socket shape clearly determines the alignment of the plug see Figure 44 Figure 44 Now fix the connecting cable 12 as shown in Figure 43 step II using the cable binder 10 as traction relie...

Страница 17: ...t make sure that it is laid below the base part up to the passage hole in the cabinet Notice The turnament to fix the base part 11 must not exceed 1 3 Nm Notice To fasten the base part only the enclosed screws 9 whose screw head size match exactly the input unit should be used Should you use any other screws you have to make sure that the screw head height does not exceed 2 6 mm since otherwise th...

Страница 18: ...8 Mounting the rotary handle Check the O ring 3 seat once again 5 8 mm from the front edge of the shaft Then insert the rotary handle 7 and lock it into place In doing so make sure that in the locked state of the lock 1 the KABA logo or the opening indication 15 small depression is horizontal Should the rotary handle 7 not lock into place do not apply force but check the length of the shaft the co...

Страница 19: ...entioned for the user in the instructions of the secure storage unit or in additional documents In addition to that the set master code can be documented in the operating instructions of the lock For more information on this please refer to the area highlighted in gray in chapter 1 page 4 Master code set by the distributor or manufacturer of the safe and chapter 15 15 Functional test The function ...

Страница 20: ...40 Mounting instructions 82132 3xxx CB 30 CLAVIS Deutschland GmbH Schillerstraße 47 51 34117 Kassel Telefon 49 0 561 988 499 0 Fax 49 0 561 988 499 99 E Mail info tresore eu Internet www tresore eu www tresorschloss de Kundendienst ...

Отзывы: