background image

4

oPen and Close The X-10

 (factory Combination)

If you have not read the section on “Dialing the X-10”, it is important that you do so 
before proceeding�

Note: The lock is shipped preset to operate in the Single Combination Mode with a 
Default Factory Combination of 50-25-50. 

TO OPEN THE LOCK (using the Factory Combination):

CW=ClockWise; CCW=CounterClockWise

1 Dial left (CCW) until lock is “powered” The lock is considered “powered” when 

numbers appear on the LCD display screen

2 Continue dialing left  (CCW) to the first number of the factory combination (50)Stop 

on 50 and pause briefly

3 Dial right (CW) to the second number of the factory combination (25) Stop on 25 and 

pause briefly

4 Dial left (CCW) to the third number in the factory combination (50) Stop on 50 and 

pause briefly 

5 Dial right (CW) After OP with a right arrow (OPen right) is displayed, continue dialing 

to the right to retract the lock bolt

Note: If at any time the dial remains stationary for more than 40 seconds, the lock will 
power down (LCD will go blank), requiring the operator to redial the entire combination.

TO CLOSE THE LOCK:

1 Turn Dial to the left (CCW) a minimum of one complete revolution to extend the bolt 

and wait 3 seconds

2 Turn Dial to the right (CW) a minimum of one complete revolution to ensure that it is 

locked 

Note: The Dial should turn freely in either direction without catching or binding when 
the bolt is extended and the lock is closed. 

Practice opening and closing the lock several times with the preset factory combination before 

you set a new combination When you feel comfortable opening the X-10 using the preset 

factory combination, you are ready to put the lock into operation

Содержание X-10

Страница 1: ...OPERATING INSTRUCTIONS X 10TM Type 1F HIGH SECURITY ELECTRONIC LOCK...

Страница 2: ...e Key in the Safe 8 Using the X 10 9 Single Combination Mode 9 Dual Combination Mode 9 Supervisory Subordinate Mode 10 Correct Method of Closing Relocking Container 11 Audit Features of the Lock and F...

Страница 3: ...ngle Combination Mode with a Default Factory Combination of 50 25 50 The 8 digit lock serial number is located on a removable sticker on the lock case See Figure 1 Which is designed for the security p...

Страница 4: ...and if the number of consecutive unsuccessful attempts is three or more the unsuccessful attempts count will be displayed along with a lightning bolt You must slow down or stop dialing to pause and v...

Страница 5: ...before the lock bolt is retracted B A lightning bolt is displayed Caution An X 10 lock will initiate a timed lockout of 3 minutes when ten consecutive wrong combinations have been dialed Each additio...

Страница 6: ...nation 50 Stop on 50 and pause briefly 5 Dial right CW After OP with a right arrow OPen right is displayed continue dialing to the right to retract the lock bolt Note If at any time the dial remains s...

Страница 7: ...on can be entered again to disable lock access Lock Up LU In this state the Subordinate Combination will no longer open the lock SET OPERATING MODE and change combinations Use the Change Key See Figur...

Страница 8: ...Example B on Page 3 when dialing to select the mode Using the Serial Number to Set Operating Mode and Combination If you have lost or forgotten the current combination s you can use the serial number...

Страница 9: ...the combinations may be the same In Supervisory Subordinate Mode Supervisory Combination must be entered first and the Supervisory and Subordinate Combinations cannot be the same combination 1 Dial r...

Страница 10: ...Key sequence in any way the X 10 automatically reverts to the previous combination s The old combination s remain valid until the process is completed successfully Caution After you have confirmed the...

Страница 11: ...quiring the operator to redial the entire combination DUAL COMBINATION MODE In this mode two combinations must be correctly and consecutively entered to open the lock Either combination may be entered...

Страница 12: ...en the lock i e left CCW to dial the first number right CW to dial the second number left CCW to dial the third number EXAMPLE Combination 25 50 75 Dial left to first number 25 Stop Dial right to seco...

Страница 13: ...LU Locked Up will be displayed indicating the lock cannot be opened The Subordinate Combination will not open the lock again until the Supervisory Combination is redialed to UnLock UL the lock once a...

Страница 14: ...number of unsuccessful attempts to open the lock This count will only be displayed when there have been three or more consecutive unsuccessful attempts The lock bolt must be extended before starting...

Страница 15: ...olts Lock in Penalty Mode Timed Lock Out UL Unlocked LU Lock Up Key Change Key Symbol The Change Key has been inserted and the lock is in Change Combination Mode SL Select Mode of Operation EC Enter C...

Страница 16: ...tice The information in this manual is subject to change without notice and does not represent a commitment on the part of Kaba Mas Kaba Mas shall not be liable for technical or editorial errors or om...

Отзывы: