12
A
UDIT
F
EATURES
OF
THE
L
OCK
The X-09 lock tracks the number of successful openings for the lifetime of the lock. It also
tracks the number of consecutive unsuccessful attempts and will alert you upon lock power
up if there have been 3 or more consecutive unsuccessful attempts to open the lock.
The
lock bolt must be extended and the lock allowed to power down prior to obtaining an
audit count of any type.
TO CHECK THE NUMBER OF SUCCESSFUL OPENINGS
The number of successful openings is a four digit number that will be displayed two digits
at a time. The lock bolt must be extended before starting the operation.
1. Allow the lock to power down. (After 40 seconds, the display will go blank. Wait an
additional 2 minutes for full power down.)
2. Dial
continuously
to the
right
(CW) until the LCD display alternately fl ashes two pairs
of numbers. The number with the arrow fl ashing left represents the fi rst two numbers
of the successful openings count. The number with the arrow fl ashing right represents
the last two numbers in the successful openings count.
Example:
A display showing 00 (arrow left) and 15 (arrow right) means the lock has
been successfully opened a total of 0015 times.
The number of successful openings will refl ect the total number of times the lock has been
opened since it was manufactured. When the lock has been opened 9,999 times, the next
time that the lock is opened the count will begin again at 0 and continue to increment.
TO CHECK THE NUMBER OF UNSUCCESSFUL ATTEMPTS
The X-09 keeps a record of the number of unsuccessful attempts to open the lock.
This count
will only be displayed when there have been three or more consecutive unsuccessful
attempts.
The lock bolt must be extended before starting the operation.
1. Allow the lock to power down. (After 40 seconds, the display will go blank. Wait an
additional 2 minutes for full power down.)
2. Dial
left
(CCW) until lock is “powered”. If 3 or more consecutive unsuccessful attempts
have occurred, a lightning bolt along with the two digit count will be displayed.
Note:
An X-09 lock will register an error condition and will intitiate a timed lockout
of 3 minutes when ten consecutive unsuccessful attempts to open the lock are
made. Each additional unsuccessful attempt will initiate another timed lockout. If
the number of consecutive unsuccessful attempts reaches fi fteen, the timed lockout
increases to 4 minutes. The lockout period is only timed while the lock is powered.
The unsuccessful attempts count resets to 0 only when the lock is successfully
opened. If the number of unsuccessful attempts exceeds 99, the count will remain
at 99 until reset.
Once the count is displayed, you may continue dialing left to start dialing a combination.
Содержание X-09
Страница 1: ...OPERATING INSTRUCTIONS X 09TM Type 1F HIGH SECURITY ELECTRONIC LOCK...
Страница 16: ...NOTES...