22
G.
Ensure that the two small indents on the cross
are now vertically in-line. (
The cylinder or
override shaft tool can be used to turn override
shaft.)
H.
Push in the lever catch
(f)
firmly.
2 Indents
Vertical
f
Testing the Operation of the Lock
A.
Rotate inside lever and hold. Ensure that the latch is fully retracted and
flush with the latch faceplate.
B.
Release the inside lever. The latch should be fully extended.
C.
For dormakaba PowerPlex P2000, you need to activate the outside lever
3 to 4 times to power the lock prior to entering the combination.
D.
Enter the factory set combination: 1,2,3,4,5,6,7,8. You should see a
green light and hear a high-pitched tone as you push each button. When
the lock opens, you will briefly hear the sound of an electronic motor.
E.
Rotate outside lever and hold. Ensure that the latch is fully retracted
and flush with the latch faceplate.
F.
Release the outside lever. The latch should be fully extended. When the
lock re-locks, you will again hear the motor.
G.
If your product is an E24xx, you will have to generate an access code
using the web application to test the lock operation.
H.
With the door open, verify functionality of the mechanical key override
as detailed in
Install Optional K-I-L or BEST Removeable Core Override
and Outside Lever
.
Figure 21
22
Содержание DKX-10
Страница 1: ...Kaba Mas LLC DKX Series Type III Installation Instructions June 16 2020 550 1026 REV B June 2020 ...
Страница 37: ...NOTES ...