REVOLUTION  ‘A’  DIGITAL LOCK 

 

 

The lock must be in the home (Vertical) position before entering an opening code 

 

Each successful key press is acknowledged with a L.E.D. flash 

 

Three consecutive incorrect codes will result in a 5 minute lockout. Signalled by a red 
flashing L.E.D. next to the   symbol. If a further incorrect code is entered the lockout 
delay will increase to 20 minutes. 

 

The lock will reset if a gap of more than 30 seconds is left between two key presses, 
Code entry must be restarted. 

 

OPENING THE LOCK 

 

Opening the lock with no time delay 

 

1.  Enter the six digit opening code (Factory default 1-2-3-4-5-6) 
2.  Once a correct code is entered the “Ready for Opening” L.E.D. will light for 5 

seconds. 

3.  Turn the keypad 180 Degrees Clockwise 

 

Opening the lock with time delay 

 

1.  Enter the six digit opening code (Factory default 1-2-3-4-5-6) 
2.  Once a correct code is entered the “Ready for Opening” and “Delay L.E.D.s will light 

alternately for time delay period. 

3.  Once the delay period has ended the “Key Acknowledgement” L.E.D. with flash for 3 

minutes. Enter the opening code again. 

4.  Once the correct code is entered again the “Ready for Opening” L.E.D. will light for 5 

seconds. 

5.  Turn the keypad 180 Degrees Clockwise 

 
 

CLOSING THE LOCK 

 
Turn the keypad 180 Degrees anti-clockwise, back to the upright position  

 
PROGRAMMING 
 
 
 
 
 
 
 

ATTENTION!

          TESTING          

ATTENTION! 

 

ALWAYS TEST NEW CODES & PROGRAMMING WITH THE DOOR IN THE OPEN POSITION

 

 
Changing the Administrator Code 

 

1.  Enter the six digit administrator code (Factory default 1-2-3-4-5-6) 
2.  Once a correct code is entered the “Opening” L.E.D. will light for 5 seconds. 
3.  During this period, press and hold the 

‘Enter’

 button until the “Programming” L.E.D. 

comes on 

4. 

Key-in 

‘0’

 then 

‘ENTER’ 

5.  Key-in your new six-digit administrator code followed by 

‘ENTER’

 

6. 

Key-in your new six-digit administrator code again followed by 

‘ENTER’ 

7.  A successful code change is signalled by the “Ready for Opening” L.E.D. lighting up 

for three seconds. A failed code change is signalled by the “Reject” L.E.D. lighting up 
for three seconds. 

 