Adding or Over-writing a user code 
 

1.  Enter the six digit administrator code (Factory default 1-2-3-4-5-6) 
2.  Once a correct code is entered the “Opening” L.E.D. will light for 5 seconds. 
3.  During this period, press and hold the 

‘Enter’

 button until the “Programming” L.E.D. 

comes on 

4. 

Key-in the user number to add or change 

‘1’ 

to 

‘8’

 then 

‘ENTER’ 

5.  Key-in your new six-digit user code followed by 

‘ENTER’

 

6. 

Key-in your new six-digit user code again followed by 

‘ENTER’ 

7.  A successful code change is signalled by the “Ready for Opening” L.E.D. lighting up 

for three seconds. A failed code change is signalled by the “Reject” L.E.D. lighting up 
for three seconds. 

 

Deleting a user code 

 

1.  Enter the six digit administrator code (Factory default 1-2-3-4-5-6) 
2.  Once a correct code is entered the “Opening” L.E.D. will light for 5 seconds. 
3.  During this period, press and hold the 

‘Enter’

 button until the “Programming” L.E.D. 

comes on 

4. 

Key-in the user number to delete  

‘1’ 

to 

‘8’

 then 

‘ENTER’ 

5. Key-in 

ENTER’

 

6. 

Key-in 

‘ENTER’ 

again

 

7.  A successful code deletion is signalled by the “Ready for Opening” L.E.D. lighting up 

for three seconds. A failed code change is signalled by the “Reject” L.E.D. lighting up 
for three seconds. 

 

Setting the Time Delay 

 

1.  Enter the six digit administrator code (Factory default 1-2-3-4-5-6) 
2.  Once a correct code is entered the “Opening” L.E.D. will light for 5 seconds. 
3.  During this period, press and hold the 

‘Enter’

 button until the “Programming” L.E.D. 

comes on 

4. 

Key-in 

‘9’

 then 

‘ENTER’ 

5. 

Key in the two digit delay time 

‘00’ 

to 

‘99’ 

then 

‘ENTER’ 

(00 = No Delay)   

 

 
 
 
REPLACING THE BATTERIES 
 

It is recommended to replace the batteries as soon as the 

‘Battery Low’ 

signal shows. The low 

will operate however for at least a further 50 operations. While the low battery signal is on, no 
programming is allowed.  
 
To change the batteries, lift the cover of the battery compartment with the tip of a screwdriver. 
Install 3 off AA Alkaline type batteries paying attention to the polarity. Reinstall the battery 
cover. 

Securikey Ltd PO Box 18   Aldershot  Hampshire GU12 4SL 