6
STRIKE INSTALLATION
1. Refer to the enclosed Strike Information Sheet for your specifi c strike
mounting details.
2. Mount the strike on the door jamb at a convenient height above the fl oor. This
should not exceed 47 inches from the fl oor to the center of the strike.
3. Make sure the strike is mounted so its bolt opening is parallel to the face of the
door and positioned to allow for the bolt elevation from the face of the door.
REFER TO THE “INSTALLATION DETAIL TEMPLATE”. Please note that the 7/8
inch dimension includes the 0.125 inch thick hardplate.
TEMPLATE
An “INSTALLATION DETAIL TEMPLATE” with dimensional information is included
in this kit. An actual size, cardboard, cut-out template is also included for
your convenience.
DEAD BOLT INSTALLATION
1. Use the center of the strike as a reference to position the cardboard
TEMPLATE on the door.
NOTE:
THE DOOR MUST BE AJAR AND FREE TO SWING WHILE POSITIONING THE
TEMPLATE TO THE STRIKE AND THE DOOR.
2. Fit the strike opening of the template over the strike (i.e., center the strike in
the opening) and tape the template to the door.
3. Center punch all hole positions onto the door.
4. Drill the 1/2" diameter spindle hole through the door.
5. Drill the two (2) CDX-09 attaching screw holes nearest the strike opening (No.
25 drill, 0.149 inch diameter). Drill holes only 1.25 inches deep.
DO NOT
DRILL THROUGH.
6. Drill the other four (4) CDX-09 attaching screw holes (11/32 inch drill, 0.344
inch diameter) through the door. The Exterior Mounting Plate posts will extend
into these holes from the opposite side of the door.
7.
IF YOU ARE INSTALLING AN EXTERIOR “DRILL RESISTANT” MOUNTING
PLATE
with your CDX-09 Lock, you must also counterbore the four (4) 11/32"
diameter holes in your door that receive the four (4) studs on the back of the
mounting plate. The counterbore is required on the OUTSIDE of the door and
must be 1/2" diameter x 1/8" deep.
8. Remove the X-09 lock cover and lay it aside.
BE CAREFUL TO NOT TOUCH
ANY OF THE CONNECTOR PINS ON THE ELECTRONIC CARD INSIDE
THE COVER.
9. Remove the protective padding from the end of the cables.
10. Place the outer tube over the cable and onto the tube retainer on the back of
the lock case with the fl ared end toward the lock case.
11. Place the 3.5 X 5 x 1/8 inch hardplate against the back of the CDX-09 base.