1.7 Machine setup menu
Page 34
Docu-No.: 0590020601-EN Rev. 1.6.0
1.7
Machine setup menu
This menu programs the feeder specific information. The data is
arranged in three separate screens or menus.
1.7.1
General sub-menu
Parameter
Definition
SETPOINT MODE
Setpoint Mode
Setting
Meaning
LOCAL
Feeder is operated as an individual unit.
RATIO
Percentage of an external analog setpoint input =
operating setpoint.
DIRECT
External analog setpoint input = operating setpoint.
LINE1-8
Feeder Setpoint is entered from the Line overview
Page. In this mode the feeder is assigned to a line.
It's called recipe mode. Use Line1 for KSL.
Input range: See list Default Local
MAX SETPT
Maximum Setpoint
Input of a maximum permissible setpoint value.
This value depends on the maximum throughput performance of the
feeder.
Note:
This value also scales the ratio setpoint input and massfow
and setpoint analog outputs.
Input range: 0 to 999999 kg/h Default: 7200 kg/hr.
UNITS
Units Selection
Selection of the desired units.
Note:
This selection change automatically all weight specific units.
Setup:
kg/h, kg/min, lb/h, lb/min, T/h (metr. Ton), ET/h (engl. Ton), gr/h, gr/
min.
Input range: See list Default kg/h
RUN TIME-[hours]
Feeder Run Time
Display of the total run time in hours. A value may be entered as a
baseline.
Input range: Normal Display only
FDR ADDR
Feeder Number or
Feeder Address
Address of the selected KCM.
Note:
• If the KCM CPU DIP switch, positions <1> to <5> are all set to <0>,
then the feeder address is set by this entry, else it is from the DIP
switch and then this parameter is ‘read only’.
Table page 1 of 2