![K-TEK KP Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/k-tek/kp/kp_installation-and-operation-manual_648644006.webp)
KP-0200-1 Rev f (10-2010) DCN0536
6
D. Side Bin Wall Mounting
1. If flange-mounting plate is used, fully assemble the paddle switch by connecting the paddle to the
power shaft and secure with a 1/8” roll pin.
2. Insert the paddle end of the assembly through the 5-1/2” clear opening and align the flange mount-
ing bolt holes such that the conduit entries on the enclosure are located either on top or the right
hand side when looking at the outside bin wall.
Note:
The use of a 1/8” gasket is recommended
between the mounting flange and bin wall to reduce vibration transmission.
3. Screw in the six mounting bolts and tighten. The final assembly should be installed as per
Figure 2
.
4. If a half pipe-coupling fitting is to be used, the paddle must be removed prior to insertion and assem-
bled after the paddle housing is secured to the bin wall.
Note:
Special care should be taken to en-
sure that the paddle assembly is tightened into the pipe coupling by wrench tightening at the ma-
chined flats (1-1/8”) below the bottom of the housing only.
DO NOT
tighten the housing into the cou-
pling by turning the housing itself.
3/4" CONDUIT ENTRY
1/8" GASKET
RECOMMENDED
BIN WALL
HALF PIPE
COUPLING
FLEX COUPLING
(OPTIONAL)
PADDLE
MOUNTING FLANGE
(MOUNTING BOLTS
NOT SHOWN)
FIGURE 2
Figure 2