K-Stove® is a brand of DMS-Europe BV
NL-3641AR-2 The Netherlands
34
problems, start the stove again:
problems
reason
solution
1. The start light or
display does not light
when power is on
No power in stove or in the
control panel.
Check the power and wires.
Fuse is broken
Replace the
fuse
2. The blower doesn’t
work after pressing the
start bottom.
If after stabilization, it
doest work, there must be
wrong
It is normal.
It will start automatically
when the temperature is
above 30 degrees on the
venting pipe.
Please wait
No power in stove or in the
control panel.
Or Unplugged on the mother
board
The low temperature sensor is
broken
Check the power and wires.
Plug it
Replace it
3. No feeding after 20 seconds of starting.
There are three stages for the feeding process.
One is during the several minutes, feeding is constantly. "Feeding" is showing on the LCD