The pipe should not be longer than approx. 4m in total to guarantee adequate air feed and
not have too many bends.
●
Should the line lead into the open air, it must end with a vertical 90° downward elbow or
with a wind guard.
Should one or more of these conditions NOT be applicable then usually poor combustion will
occur in the stove, as well as air under pressure in the apartment.
We recommend that a ventilating grille be fitted in a window near the stove for permanent
ventilation. Further it is possible to extract the combustion air directly from outside or from
another room that is well ventilated (e.g. the cellar).
Please observe:
Your pellet stove works independent of the room air. Negative pressures in the set-up room
are not permissible. Therefore the use of a safety device (e.g. differential pressure controller)
in combination with room air facilities (e.g. ventilation system, exhaust extraction etc.) is
stipulated.
5. Operation
ALL NATIONAL AND LOCAL REGULATIONS AND
EUROPEAN STANDARDS SHALL BE COMPLIED WITH WHEN
OPERATING THE APPLIANCE
Attention: When the stove in operation ,please don't touch the front
of it. Its extremely hot!
Note: When first time’s running, the paint can be get rid of by burning. So some
unpleasant Smell might come out. Please open the window and door to vent the smell.
Note: If the new stove, when its first time using, it is necessary to put a handful of
wood pellet to the fire pot before hand.
Note: Keep the fire pot and its underneath clean when every time you start the stove!
Put wood pellet fuel into the hopper, connect the power. Then On/Off Light is Lighting (It means