8. Operation
All these software parameters must be set directly on the hardware device. The sub
menu “User preset” where you can set parameters like gain, crossover frequency, limiter,
delays,…appears from preset no. 5 - 8.
The names of the menu points refer to the user navigation on the device.
Main Menu
•
Pot Lock Mode
[to be activated by using “lock function”, see page 13]
Pot locked
[just lock volume pot]
Pot unlocked
[just unlock volume pot]
In this menu item you can set a „lock - function“ for the volume pot of VL 750 / VL 760.
•
Sig LED Threshold
Here you can set the threshold value where the LED starts to light green when the set value is
reached by the audio signal.
•
User LED Threshold
Here you can set the threshold value where the LED starts to light blue when the set value is
reached by the audio signal. This function allows you to set an optical limit for the volume level
for your audience, e.g. -10 dB – you know your pre-set value is reached.
•
Power Mode
Last State
Audio Trigger
Always On
In this menu item you can pre-set the operating status of the VL 750 / VL 760:
If you choose „Last State“- mode, the VL 750 / VL 760 will always start in the last state of
operating after power cycle the unit (after power cycle the unit is muted!).
To reduce the power consumption e.g. in installations you can choose „Audio Trigger“- mode.
In this mode you can set a threshold value and a time value where the system automatically
switched off when the threshold is not exceeded with an audio signal. After the pre-set time the
unit is switched off. If the pre-set threshold value is exceeded during the unit is still on, the time
value counts again - that means this function is a posttrigger-function. You can switch on the
unit again by pressing the OK-button or playing an audio signal which has a higher input level
as the pre-set threshold value.
If you choose „Always On“, the VL 750 / VL 760 is always on. That means after apply power
supply the unit is automatically on and ready to play (the “lock function” can be active!).
•
Display Mode
Output Levels
headroom display]
Operation Parameters
[input level display and operation display]
You can chose between two layouts of the LCD graphic display. The first one shows the
headroom of both amplifier modules. The second one gives an overview about input level and
signal (analogue or digital) as well as temperature of the amplifiers and PSU
(PowerSupplyUnit). If the unit is muted, the operation parameter screen is displayed
automatically.
•
Diagnostics
In this menu item you can read out the current software version.
•
Factory Reset
Device Settings only
[Restore all adjustable parameters in the main menu]
All (incl.Presets)
[Reset all changes made, incl. all user presets]
To reset the unit to the programmed initial state there are two “levels”, just to restore only the
adjustable parameters in the main menu or all menu items (incl. all user presets). After resetting
all changed settings from the user are turned to the programmed initial state!