10
•
Power Management:
Mode: Always On
[after applied power supply connection the DA 230 is switched on]
Last State
[DA 230 starts in the last state of operating]
Audio Trigger
[depending on the input level the DA 230 switched automatically
on or off]
Trigger Level
[enter threshold value for Trigger Time – valid for all channels]
Trigger Time
[adjust remaining On-time]
In this menu item you can pre-set the operating status of the DA 230:
If you choose „Always On“, the DA 230 is always on. That means after apply power supply
connection the unit is automatically on and ready to play (the “lock function” can be active!).
If you choose „Last State“- mode, the DA 230 will always start in the last state of operating after
power cycle the unit.
To reduce the power consumption e.g. in installations you can choose the „Audio Trigger“-
mode. In this mode you can set a threshold value and a time value where the system
automatically switched off when the threshold is not exceeded with an audio signal. After the
pre-set time the unit is switched off. If the pre-set threshold value is exceeded during the unit is
still on, the time value counts again - that means this function is a posttrigger-function. You can
switch on the unit again by pressing the OK-button or playing an audio signal which has a
higher input level as the pre-set threshold value. Trigger source for the pre-set time value are all
channels.
•
System:
Input Mode
[only for channel A]
In A analog, In A digital, In A auto detection
Here you can switch the input A to „analogue“ or „digital“ or „auto detection“. By doing this, you
have the possibility to apply an analogue or digital audio signal on input A. If you are choosing
the menu item „auto detection“ the DA 230 detect automatically the input signal. That means
you do not have to switch the input manually to digital or analogue. On input B you can only
operate with an analogue audio signal. You will find more information on page 14.
Link Mode / Content
[only for link A]
Source, A:B/d1, A+B/d1 mono
The link mode of the DA 230 offers comprehensive possibilities for controlling the audio signal
to analogue or digital systems. You will find detailed information in the table on page 12.
Password
In this menu item you can enter a max. 8-digit password. If you have entered a password and
activate the “lock function” you have to enter the password again to unlock the unit. You will find
detailed information on page 15.
RSNC baud rate
[adjustment of communication parameter of the serial interface]
Brightness
[adjust brightness of the LCD graphic display]
Contrast
[adjust contrast of the LCD graphic display]
•
Software:
Firmware Version
Firmware Update DSP
Update i²C EEPROM