Example: 

 
Main PA system could be a K.M.E. CA 6, both top units CSA 400 D are equipped 
with DDM modules. Both modules are switched to ‘external’ operation mode 
 
In the delay speaker positions work two additional K.M.E. CSA 400 D 
 
 
You will need the following cable connections: 
 

• 1 balanced audio line (XLR) running from Line-Out [8] on the DDM 

to the Line-In of the CSA 400 D at the delay position 

• mains power line to the CSA 400 D at the delay position  
 

1.) Set the unit on the DDM to ‘meters’ [4] 
2.) Set the DDM to „EXTERNAL“ operation mode [5] 
3.) Set the estimated delay distance [3], [2] 
4.) Turn DOWN the volume of BOTH CSA 400 D 
5.) Activate the test tone function [6] 
6.) Turn up the volume on the main PA until the test tone is audible at the position 

of the delay speaker. Turn up the volume on the delay speaker until you hear 
the signal in the same sound pressure level than the signal from the main PA  

7.) Fine-adjustment of the delay time (distance) using + / - keys [3], [2], until only 

one sound pulse (without “echo”) is audible – ready. 

8.) Turn off test tone [6] and turn up the volume of both systems as necessary. 
9.)  

 
 
 
 

 

 
 
 
 
 
 

 

Содержание CSA 400 D

Страница 1: ...User Manual DDM Digital Delay Module for CSA 400 D QSA 200 D QSA 500 D ...

Страница 2: ... the blind plate on the rear side of the CSA 400 D Pull out the blind plate carefully without overstretching the multipin cable mounted to the plate remove the multipin cable from the blind plate carefully Take the DDM and plug in the multipin cable to the white socket Take care of the polarity The connector only fits in one direction Do not use tools or force to connect it The remaining red wire ...

Страница 3: ...delay time by one unit 4 unit selector switch meters Milliseconds feet 5 functional mode switch internal external 6 test tone switch on off 7 balanced audio input on DDM 8 balanced audio output on DDM DIGITAL DELAY MODULE DDM INPUT OUTPUT CLEAR VALUE CALIBRATION OFF TONE SIGNAL INT EXT DELAY MODE ON DISPLAY m ms ft 330 0 m DELAY ...

Страница 4: ...d internal external either the un delayed or delayed signal You can connect other equipment like self powered speakers or amplifiers together with passive speaker systems b Functional mode switch 5 Internal Mode PLUG IN 0 330 m PLUG IN Main PA Delay Line External Mode PLUG IN 0 330m PLUG IN Main PA Delay Line The external mode supplies the delayed audio signal on the DDMs line out The speaker itse...

Страница 5: ...y time setting 2 3 The delay time needed can be set easily by pressing the plus or minus key Holding the keys increases or decreases the value by larger amounts It is possible to adjust the delay distance by 0 1 m 10 cm within an range of 330 m or by 1 ms or by 1 ft which should be ideal for all sound reinforcement applications 330 0 m DELAY 0 0 m DELAY e Test tone mode for setting the correct del...

Страница 6: ...ition 1 Set the unit on the DDM to meters 4 2 Set the DDM to EXTERNAL operation mode 5 3 Set the estimated delay distance 3 2 4 Turn DOWN the volume of BOTH CSA 400 D 5 Activate the test tone function 6 6 Turn up the volume on the main PA until the test tone is audible at the position of the delay speaker Turn up the volume on the delay speaker until you hear the signal in the same sound pressure ...

Страница 7: ......

Страница 8: ...48 Klingenthal Germany phone 49 0 37467 558 0 fax 49 0 37467 558 33 www kme sound com service kme sound com Technical State February 2005 The content corresponds to the state at printing Subject to technical alterations Misprints and errors expected Feb 2005 SL ...