background image

19

 

◦ The Win7 64-bit graphics driver is located in the directory: x:\Driver Installation\

PXI Platform\PXI controller\PXIe-63985\Win7_64bit\Graphics\

3.  Execute setup.exe and follow on-screen instructions tocomplete the setup
4.  Reboot the system

3�4    Installing the Ethernet Driver

To install the Ethernet driver:

1.  Close any running applications.
2.  Insert the JYTEK All-in-One USB Flash Driver (x: denotes the USB driver)

 

◦ The Win7 32-bit Ethernet driver is located in the directory: x:\Driver Installation\

PXI Platform\PXI controller\PXIe-63985\Win7_32bit\LAN\

 

◦ The Win7 64-bit Ethernet driver is located in the directory: x:\Driver Installation\

PXI Platform\PXI controller\PXIe-63985\Win7_64bit\LAN\

3.  Execute  PROWin32.exe  or  PROWin64x.exe  and  followon-screen  instructions  to 

complete the setup.

4.  Reboot the system

 

3�5    Installing the GPIB Driver

The  PXIe-63985  controller  features  an  onboard  GPIB  controller,  providing  connectivity 

between PXI and GPIB instruments. The GPIB driver package also contains function libraries 

and a utility to interact with GPIB instruments.
To install the GPIB driver:

1.  Close any running applications.
2.  Insert the JYTEK All-in-One USB Flash Driver (x: denotes the USB driver)

 

◦ The Win7 32-bit GPIB driver is located in the directory: x:\Driver Installation\PXI 

Platform\PXI controller\PXIe-63985\Win7_32bit\GPIB\

 

◦ The Win7 64-bit GPIB driver is located in the directory:  x:\Driver Installation\PXI 

Platform\PXI controller\PXIe-63985\Win7_64bit\GPIB\

3.  Execute setup.exe and follow on-screen instructions tocomplete the setup
4.  Reboot the system

 

3.6    Installing the Management Engine Driver

To install the management engine driver:

1.  Close any running applications.
2.  Insert the JYTEK All-in-One USB Flash Driver (x: denotes the USB driver)

Содержание PXIe-63985

Страница 1: ...PXIe 63985 PXI Express Embedded Controller User s Manual Manual Rev 1 00 Revision Date Jul 16 2016 ...

Страница 2: ...203 China Tel 86 21 5047 5899 Fax 86 21 5047 5899 Email service jytek com Additional information aids and tips that help users perform tasks Information to prevent minor physical injury component damage data loss and or program corruption when trying to complete a task Informationtopreventseriousphysicalinjury componentdamage dataloss and or program corruption when trying to complete a specific ta...

Страница 3: ...e 63985 14 2 2 3 Replacing the Hard Drive or Solid State Drive 15 2 2 4 Replacing the Battery Backup 16 2 2 5 Clearing CMOS 17 3 Driver Installation 18 3 1 Installing Windows Drivers 18 3 2 Installing the Chipset Driver 18 3 3 Installing the Graphics Driver 18 3 4 Installing the Ethernet Driver 19 3 5 Installing the GPIB Driver 19 3 6 Installing the Management Engine Driver 19 3 7 Installing the P...

Страница 4: ...RIG_GetSoftTrg 26 A 2 7 TRIG_Trigger_Route_Query 26 A 2 8 TRIG_GetDriverRevision 28 Appendix B BIOS Setup 29 B 1 Starting the BIOS 29 B 2 Main Setup 30 B 3 Advanced Setup 31 B 4 Boot Setup 32 B 5 Security Setup 32 B 6 Save Exit Setup 33 Important Safety Instructions 34 ...

Страница 5: ...le 1 5 USB 2 0 Port Pin Assignment 9 Table 1 6 PXIe 63985 Ethernet Port Pin Assignments 9 Table 1 7 D Sub 9p COM Port Signal Functions 11 Table 1 8 Onboard Configuration Legend 12 Table B 1 BIOS Hot Key Functions 30 Table B 2 BIOS Main Setup Menu 31 Table B 3 BIOS Advanced Setup Menu 32 Table B 4 BIOS Boot Setup Menu 32 Table B 5 BIOS Security Setup Menu 32 ...

Страница 6: ...Diagram 2 Figure 1 2 PXIe 63985 Front Panel 5 Figure 1 3 PXI Trigger SMB Jack 6 Figure 1 4 DisplayPort Connector 6 Figure 1 5 PXIe 63985 LED Indicators 8 Figure 1 6 COM Port 11 Figure 1 7 PXIe 63985 Onboard Configuration 12 Figure B 1 BIOS Setup Navigation 30 ...

Страница 7: ... including two DisplayPort connectors allowing connection to two monitors dual USB 3 0 connections for high speed peripheral devices dual Gigabit Ethernet ports one for LAN connection and the other for controlling LXI instruments four USB 2 0 ports for peripheral devices and USB instrument control and a Micro D GPIB connector for GPIB instrument connection for hybrid PXI based testing systems cont...

Страница 8: ...onnector GPIB SMB Connector PXIe Connector Trigger Bus Controller COM Port connector PCIe Gen2 0 48 lanes swtich 2 5 SATA Interposer Board SATA GbE connector GbE I F Digital Display I F DisplayPort connector x2 PCIe x1 PCIe Gen2 x16 Trigger Signal LPC Intel FDI DMI GbE PHY 82579 GbE controller I210 Trigger Bus DDR3 1600MHz DDR3 1600MHz USB 3 0 USB 2 0 USB3 0 connector x2 Gen2 4Links x4 Gen2 2Links...

Страница 9: ...rds are available with maximum available resolution dependent on the adapter chosen Hard Drive Built in 2 5 500GB SATA hard drive or 240GB SATA solid state hard drive I O Connectivity Dual Gigabit Ethernet controllers through two RJ 45 connectors with speed link active LED on the faceplate with both supporting Wake on LAN USB Four USB 2 0 and two USB 3 0 ports on the faceplate GPIB Onboard IEEE488...

Страница 10: ... Grms 3 axes Environmental Shock and Vibration values are only guaranteed with use of an JYTEK provided SSD HDD Certification Electromagnetic compatibility EMC EMI CE FCC Class A CE Compliance EN 61326 1 The PXIe 63985 meets the essential requirements of applicable European Directives Power Requirements Voltage Rail 5V standby 3 3V 5V 12V Maximum power consumption 0 13A 3 0A 3 9A 5 3A Typical powe...

Страница 11: ...85 Front Panel A PXI Trigger Connector SMB jack F 4X Type A USB 2 0 connectors B 2X DisplayPort Connectors G 2X Gigabit Ethernet C GPIB Connector Micro D Sub 25P H 2X USB 3 0 D Reset Button I 1X COM port D sub9 serial E LED indicators Table 1 1 Front Panel Legend ...

Страница 12: ...ed trigger bus line to PXI trigger connector From the PXI trigger connector to a selected trigger bus line From software trigger to a selected trigger bus line From software trigger to PXI trigger connector All trigger modes are programmable by the provided driver Please refer to Section A PXI Trigger I O Function Reference for further information DisplayPort Connectors Provide monitor connection ...

Страница 13: ...troller provides Full compatibility with IEEE 488 standard Up to 1 5MB s data transfer rates Onboard 2 KB FIFO for read write operations Driver APIs are compatible with NI 488 2 driver software Connection with up to 14 instruments 1 13 14 25 Pin Signal Description Pin Signal Description 1 DIO1 GPIB Data 1 14 DIO5 GPIB Data 5 2 DIO2 GPIB Data 2 15 DIO6 GPIB Data 6 3 DIO3 GPIB Data 3 16 DIO7 GPIB Da...

Страница 14: ...lor Description PW Green Indicates system power remaining lit when the system boots normally and main power supply is functioning HD Yellow Indicates operating state of the HDD or SSD flashing during access to or activity on the SATA HDD USR Blue User programmable LED indicator Table 1 4 LED Indicator Legend 1 3 5 USB 2 0 Ports The PXIe 63985 provides four USB 2 0 ports via USB Type A connectors o...

Страница 15: ... 1 3 6 Gigabit Ethernet Ports Dual Gigabit Ethernet connection is provided on the PXIe 63985 front panel Pin 1000Base T Signal 100 10Base T Signal 1 MDI0 TX 2 MDI0 TX 3 MDI1 RX 4 MDI2 Reserved 5 MDI2 Reserved 6 MDI1 RX 7 MDI3 Reserved 8 MDI3 Reserved Table 1 6 PXIe 63985 Ethernet Port Pin Assignments ...

Страница 16: ...ted with data transmitted received Speed Green Or ange Off 10 Mbps Green 100 Mbps Orange 1000 Mbps 1 3 7 USB 3 0 Ports The PXIe 63985 provides two Type A USB 3 0 ports on the front panel supporting SuperSpeed Hi Speed full speed and low speed transmission for downstream Multiple boot devices including USB flash USB external HD and USB CD ROM drives are supported with boot priority configured in BI...

Страница 17: ...2 RS 422 RS 485 by BIOS selection 1 5 6 9 Figure 1 6 COM Port Pin Signal Name RS 232 RS 422 RS 485 1 DCD TXD422 485DATA 2 RXD TXD422 485DATA 3 TXD RXD422 N S 4 DTR RXD422 N S 5 GND N S N S 6 DSR N S N S 7 RTS N S N S 8 CTS N S N S 9 RI N S N S Table 1 7 D Sub 9p COM Port Signal Functions ...

Страница 18: ...12 1 3 9 Onboard Connections and Settings Figure 1 7 PXIe 63985 Onboard Configuration A SATA Connector B Clear CMOS switch C System Battery Table 1 8 Onboard Configuration Legend ...

Страница 19: ...u want to ship or store the product in the future Do not install or apply power to equipment that is damaged or missing components Retain the shipping carton and packing materials for inspection Please contact your JYTEK immediately for assistance and obtain authorization before returning any product 2 2 Operating System Installation For more detailed information about the operating system refer t...

Страница 20: ...rtant Safety Instructions Only install equipment in well lit areas on flat sturdy surfaces with access to basic tools such as flat and cross head screwdrivers preferably with magnetic heads as screws and standoffs are small and easily misplaced Recommended Installation Tools Phillips cross head screwdriver Flat head screwdriver Anti static wrist strap Anti static mat JYTEK PXIe 63985 system contro...

Страница 21: ...he alignment pin on the rear of the latch can be threaded into the best fit alignment port in the chassis rail 5 Fasten the four mounting screws on the faceplate of PXIe 63985 and connect all peripheral devices 2 2 3 Replacing the Hard Drive or Solid State Drive The PXIe 63985 provides a SATA 3 0 port with a pre installed 2 5 SATA hard drive or solid state drive Replacing the HDD or SSD is accompl...

Страница 22: ...tible SATA harddrive reverse the steps and reinstall the PXIe 63985 into the PXI system 2 2 4 Replacing the Battery Backup The PXIe 63985 is provided with a 3 0 V coin cell lithium battery replacement of which is as follows 1 Turn off the PXI chassis 2 Remove the PXIe 63985 embedded controller fromthe chassis Observe all anti static precautions 3 To remove the battery gently insert a small approx ...

Страница 23: ...ear the CMOS and restore the controller BIOS to its default settings To clear the CMOS 1 Shut down the controller operating system and turn off the PXI Chassis 2 Remove the PXIe 63985 from the chassis Observe all anti static precautions 3 Locate the CMOS clear switch SW1 on the board see Section 1 3 9 Onboard Connections and Settings Move the switch from Normal position 2 B to Clear position 2 B a...

Страница 24: ...iver for PXIe 63985 The chipset driver directs the operating system to configure the Intel QM87 chipset components To install the chipset driver 1 Close any running applications 2 Insert the JYTEK All in One USB Flash Driver x denotes the USB driver The Win7 32 bit chipset driver is located in the directory x Driver Installation PXI Platform PXI controller PXIe 63985 Win7_32bit Chipset The Win7 64...

Страница 25: ...e the setup 4 Reboot the system 3 5 Installing the GPIB Driver The PXIe 63985 controller features an onboard GPIB controller providing connectivity between PXI and GPIB instruments The GPIB driver package also contains function libraries and a utility to interact with GPIB instruments To install the GPIB driver 1 Close any running applications 2 Insert the JYTEK All in One USB Flash Driver x denot...

Страница 26: ... is located in the directory x Driver Installation PXI Platform PXI controller PXIe 63985 Win7_32bit TriggerIO TheWin7 64 bit PXI trigger driver is located in the directory x Driver Installation PXI Platform PXI controller PXIe 63985 Win7_64bit TriggerIO 3 Execute PXI Trigger IO setup v330 exe and follow on screen instructions to complete the setup 4 Reboot the system 3 8 Installing the USB 3 0 Dr...

Страница 27: ...xe and follow on screen instructions tocomplete the setup 4 Reboot the system 3 10 Installing the RST Driver To install the RST driver 1 Close any running applications 2 Insert the JYTEK All in One USB Flash Driver x denotes the USB driver The 32bit Win7 RST driver is located in the directory x Driver Installation PXI Platform PXI controller PXIe 63985 Win7_32Bit RST The 64bit Win7 RST driver is l...

Страница 28: ...anges and corresponding data types in C C Visual Basic and Delphi for reference Type Description Range Type C C for 32 bit compiler Visual Basic Pascal Delphi U8 8 bit ASCII character 0 to 255 unsigned char Byte Byte I16 16 bit signed integer 32768 to 32767 short Integer SmallInt U16 16 bit unsigned integer 0 to 65535 unsigned short Not supported by BASIC use the signed integer I16 instead Word I3...

Страница 29: ...must be called before the invocation of any other trigger I O function Syntax C C I16 TRIG_Init Visual Basic TRIG_Init As Integer Parameter None Return Code ERR_NoError ERR_BoardBusy ERR_OpenDriverFail ERR_GetGPIOAddress A 2 2 TRIG_Close Description Closes trigger I O function of PXIe 63985 controller releasing resources allocated for the trigger I O function Users must invoke TRIG_Close before ex...

Страница 30: ...iption Routes the trigger signal between the trigger I O SMB connector on the faceplate and the PXI trigger bus on the backplane This function also allows routing of the software generated trigger signal to SMB connector or trigger bus Syntax C C I16 TRIG_Trigger_Route U32 source U32 dest U32 halfway Visual Basic TRIG_Trigger_Route ByVal source As Long ByVal dest As Long ByVal halfway As Long As I...

Страница 31: ...igger bus 4 PXI_TRIG_VAL_TRIG5 PXI trigger bus 5 PXI_TRIG_VAL_TRIG6 PXI trigger bus 6 PXI_TRIG_VAL_TRIG7 PXI trigger bus 7 halfway Halfwaypointoftriggerrouting Thisparameterisusedonlytoroutethesoftware generated trigger signal to the SMB connector on the faceplate In this case the halfway should be set as one of the trigger bus lines otherwise as PXI_TRIG_VAL_NONE Available value Description PXI_T...

Страница 32: ... current software trigger state with default state after system boot of Logic Low Syntax C C I16 TRIG_GetSoftTrg U8 Status Visual Basic TRIG_GetSoftTrg status As Byte As Integer Parameters Status Returns the logic level of software trigger signal Returned value 0 Logic low 1 Logic high Return Code ERR_NoError ERR_BoardNoInit ERR_Query_Status A 2 7 TRIG_Trigger_Route_Query Description Acquires the ...

Страница 33: ... PXI_TRIG_VAL_TRIG5 116 PXI_TRIG_VAL_TRIG6 117 PXI_TRIG_VAL_TRIG7 118 dest Returns to the current destination of trigger routing with possible values including Available Definition Defined Value PXI_TRIG_VAL_NONE 0 PXI_TRIG_VAL_SMB 2 PXI_TRIG_VAL_TRIG0 111 PXI_TRIG_VAL_TRIG1 112 PXI_TRIG_VAL_TRIG2 113 PXI_TRIG_VAL_TRIG3 114 PXI_TRIG_VAL_TRIG4 115 PXI_TRIG_VAL_TRIG5 116 PXI_TRIG_VAL_TRIG6 117 PXI_T...

Страница 34: ...or2 Syntax C C I16 TRIG_GetDriverRevision unsigned short major unsigned short minor1 unsigned short minor2 Visual Basic TRIG_GetDriverRevision major As Integer minor1 As Integer minor2 As Integer As Integer Parameters major Returns the major version number of the pxi trigger software driver minor1 Returns the first minor version number of the pxi trigger software driver minor2 Returns the second m...

Страница 35: ...reen There are several cases that use other keys such as F1 F2 and so on The main BIOS setup menu is the first screen that you can navigate Each main BIOS setup menu option is described in this user s guide The Main BIOS setup menu screen has two main frames The left frame displays all the options that can be configured Grayed options cannot be configured Blue options can be The right frame displa...

Страница 36: ...legend by default To set the Fail Safe settings of the BIOS press the F8 key on your keyboard It is located on the upper row of a standard 101 keyboard The Fail Safe settings allow the motherboard to boot up with the least amount of options set This can lessen the probability of conflicting settings B 2 Main Setup When you first enter the Setup Utility you will enter the Main setup screen You can ...

Страница 37: ... the submenu for that item Display an Advanced BIOS Setup option by highlighting it using the Arrow keys The Advanced BIOS Setup options are as follows Item Detail Holdoff Timer Delay setting for PCIe discovery in seconds Launch PXE OpROM Enables or disables legacy network device default is Disabled Launch Storage OpROM Enables disables the option for Legacy Mass Storage Devices with option ROM de...

Страница 38: ...re Allows Option ROMs to trap Int 19 Set Boot Priority 1st Boot Allows selection of the primary boot source default is the SATA HDD 2nd Boot Allows selection of the secondary boot source default is Disabled Hard Drive BBS Priorities Sets the order of legacy devices in this group Table B 4 BIOS Boot Setup Menu B 5 Security Setup The system can be configured to require all users to enter a password ...

Страница 39: ...ave Changes and Reset Save Option Save Changes Discard Changes Restore Defaults Save as User Defaults Restore User Defaults The Restore the default values for all setup options selection does not restore the original boot priority sequence You must use the Boot Setup Menu see Section B 4 Boot Setup to manually restore the boot priority sequence ...

Страница 40: ... power source settings Always install and operate equipment near an easily accessible electrical socket outlet Secure the power cord do not place any object on over the power cord Only install attach and operate equipment on stable surfaces and or recommended mountings and If the equipment will not be used for long periods of time turn off and unplug the equipment from its power source Never attem...

Отзывы: