background image

9

/

12

RS485 Modbus

JXBS-3001-TH--RS Temperature Humidity Sensor User Manual

The factory default is to provide 0.6 meters long wire rods. Customers can extend the wire rods as required

or sequentially.

Note that there are no yellow lines in the wire sequences that may be provided in some factory batches, in

which case the gray line is equivalent to replacing the yellow line.

2.3 Installation

The economical version of the sensor is in the form of a standard rail mount, which snaps the back side of the
sensor onto the rail.

The 86-shell wall-mounted large-screen sensor adopts the installation form of the inverted hoist hole, and the
customer can mount the screw with a distance of 60mm.

The wall-mounted king-shaped shell is a wall-mounted installation. The installation holes are located at the middle
positions on both sides of the device. The installation aperture is less than 4mm, and the hole distance is 105mm.
It can be installed using a 3mm self-tapping screw.

Содержание JXBS-3001-TH-RS

Страница 1: ...12 RS485 Modbus JXBS 3001 TH RS Temperature Humidity Sensor User Manual JXBS 3001 TH RS Temperature Humidity Sensor User Manual RS485 Modubus Version 2 0 Date 2020 1 1 Status Released www jxct iot co...

Страница 2: ...inear degree good waterproof performance convenient use easy installation and long transmission distance 1 2 Primary Parameters PARAMETERS TECHNICAL SPECIFICATIONS POWER SUPPLY 12 24V DC POWER 0 4W OU...

Страница 3: ...ers S20 CONTENT Minimum Typical value Maximum Unit Resolution 14bit 0 01 Linear deviation 0 3 Figure 1 Repeatability 0 1 The scope of work 40 125 Response time 63 5 30 secon d Long term drift 0 04 yea...

Страница 4: ...eresis 1 RH Non linearity 0 1 RH Figure 2 Humidity measurement accuracy under different humidity conditions As shown in the above table the deviation increases with a typical deviation of 3 in the 20...

Страница 5: ...Relative humidity at different temperatures As shown in the above table in the range of 15 to 55 degrees Celsius and 30 to 80 degrees of humidity the accuracy of humidity is the highest which is 4 5 I...

Страница 6: ...efore installation TABLE 1 List of Devices Name Number THE SENSOR DEVICE 1 12V POWER ADAPTER Optional 1 WARRANTY CARD CERTIFICATE 1 THE USB TO 485 DEVICE Optional 1 2 2 Interface Description The power...

Страница 7: ...LE 2 Wiring Sequence Line Color Description Power VCC Power supply Positive 12 24V DC GND Power supply Negative Communication 485 A 485 A 485 B 485 B Wiring method After loosening the screw insert the...

Страница 8: ...the sensor is built in 3 4 7 8 is idle Use a screwdriver to press down on the yellow buckle Insert the wire into the crimping hole and release the yellow buckle to lock the wire 2 2 3 External Probe...

Страница 9: ...llation The economical version of the sensor is in the form of a standard rail mount which snaps the back side of the sensor onto the rail The 86 shell wall mounted large screen sensor adopts the inst...

Страница 10: ...Please note that this software can only test one device at the same time After connecting the physical device click the CONNECT button to read the information In the UNCONNET state you can modify BAUD...

Страница 11: ...w modbus org 4 2 Register Address TABLE 6 Register Address 4 3 Communication example 4 3 1 Read Device Address 0x01 s Soil Temperature And Humidity TABLE 7 Inquiry Frame TABLE 8 Answer Frames Register...

Страница 12: ...Sensor User Manual Temperature FF9BH hexadecimal 101 temperature 10 1 Humidity 292H hexadecimal 658 humidity 65 8 RH Address Code Function Code Number Of Valid Bytes Humidity Value Temperature Value C...