3
/
12
RS485 Modbus
JXBS-3001-TH--RS Temperature Humidity Sensor User Manual
1.3 Probe Parameters and Selection
PRODUCT
TYPE
PROBE TYPE TEMPERATURE
ACCURACY
HUMIDITY
ACCURACY
-S20
SHT20
±0.3
℃
±3-7%
-S30
SHT30
±0.3
℃
±2-4.5%
-S31
SHT31
±0.3
℃
±2%
-S75
SHT75
±0.3
℃
±1.5-3%
1.4 Temperature Parameters
(
-S20
)
CONTENT
Minimum
Typical value
Maximum
Unit
Resolution
(
14bit
)
-
0.01
-
℃
Linear deviation
-
±0.3
Figure 1
℃
Repeatability
-
±0.1
-
℃
The scope of work
-40
-
125
℃
Response time (63%)
5
-
30
secon
d
Long-term drift
-
<0.04
-
℃
/yea
r
Figure 1 Temperature measurement accuracy at different temperatures
As shown in the above table, the maximum deviation is within ±0.5 in the range of 5-60 degrees Celsius, and the
deviation increases with less than 0 degrees Celsius and greater than 60 degrees Celsius.