XV-521BK/523GD/522SL
1-21
FE
OFF
ON
TE
OFF
ON
FE
LO LI
OK !
Y
Y
A
N
N
N
N
Y
Y
N
N
Y
Y
Y
Y
A
Y
Y
Y
N
N
N
Press key
Is tray
operation
correct?
"NO DISC" message appears
immediately after vertical
movement of the PU Lens.
Is the traverse moving
along the innermost
perimeter for SW detection?
See "3. OPEN/CLOSE
Operations", Troubleshooting.
Does it show "NO DISC" immediately?
Does it show "NO DISC" a few seconds
later without DISC rotation?
Disc rotation becomes abnormally fast.
Is focus retraction OK?
Even when it retracts
correctly, if it is out of focus
and makes repeated retries
with a clicking sound, it is
in error.
Is tracking retraction OK?
If TE waveform reappears
or fails to converge after the
TE retraction, it is in error.
Is the spindle servo
locked correctly?
Is the RF OUT waveform
locked correctly?
Two layers of DVD only.
Is the inter-layer jump OK?
(8) Inter-layer jump error
Has the disc information
been collected?
Disc change or stop
will result
(7) Address read error
Check (9), (10), (11), and (12)
items in "Checkpoints for
Individual Errors".
Is playback possible?
See "(3) Traverse Movement Error"
in "Checkpoints for Individual Errors".
See "(2) Disk Detection, Determination Error"
in "Checkpoints for Individual Errors".
See (5) "Tracking ON Error",
Checkpoints for Individual
Errors.
See "(6) Spindle CLV Error",
"Checkpoints for Individual
Errors".
See (4) "Focus ON Error" in
"Checkpoints for Individual
Errors".
See "(1) Spindle Startup Error"
in "Checkpoints for Individual Errors".
Servo volum
Troubleshooting