XV-521BK/523GD/522SL
1-15
Measurement
Adjustment point
Refer to Fig.2
Mode
Reproduction
part
Disc
Measurement machine
No need
"Flap adjustment" of the Pick-up guide shaft adjusts
"Tangential adjustment machine screw" A and
"Tilt adjustment machine screw" B from the
DVD Mechanism A'ssy bottom.
1. The part at the center on the DVD test disc is
reproduced.
2.The flap adjustment screws is turned alternately
and set the jitter value of FL indicator to its minimum.
Note
1.The tangential adjustment is done finish and,
then, tilt is adjusted.
2.The repeat the adjustment 2-3 times,for best
result.
3.The final adjustment should be tilt adjustment.
VT-501
DVD Mechanism A'ssy
Stand
Stand
200mm
Fig.1
CN101 of DVD Servo Control PWB
CN101 of
Connection PWB
Extension Cord
connections
Refer to Fig.1
Extension cord No.
General tool : Hex-head wrench(1.27mm)
Flap adjustment method
DVD Player
FL Display
Confirmation after adjustment.
Confirm to reproduce video CD and CD after
the DVD test disc is adjusted and to find abnormality.
(3) About keeping the disc
As for the DVD test disc, plane accuracy is demanded.Please note the keeping place on the disc.
1. Please do not put the disc directly on the work desk etc. after uses .
2.To keep the planarity of the disc, politely handle ,and please put in a special case and keep
the disc vertically after uses .
Please keep keeping the disc in a cool place where direct sunshine and the air-conditioning
wind do not drive.
3.When the disc curves,an accurate adjustment cannot be done.
Please exchange for a new test disc and adjust optics.
4 Other discs might not be able to be reproduced when adjusting on a curved disc.