background image

15

Others

General

Power / Voltage

: AC 24 V 50 Hz/60 Hz (Main Housing Unit)

Power Consumption

: 25 W (During heater operation, excluding 

camera)

Installation Location

: Outdoor (general)

Ambient Temperature

:

-

20 

I

 to 50 

I

 (when equipped with 

TK-C625U/E)

:

-

20 

I

 to 40 

I

 (when equipped with 

VN-C625U)

Heater Operation Temperature (Internal temperature)

: Heater turns ON between 8 

I

 ± 5 

I

Turns OFF between 20 

I

 ± 5 

I

Ambient Humidity : 35 % to 90 %

Vibration / Shock : Locations without vibration/shock

Dustproof / Waterproof

: IP66

T

When combined with compatible 
camera

Permissible Wind Speed

: 40 m/s or below

Mass: 

5.0 k

g

Accessories:

Instructions ...............................1

Desiccant..................................1

Screw (M4×20) .........................4

Hexagon wrench.......................1

Compatible Cameras: TK-C625U/E, VN-C625U

Dimensional Outline Drawing (Unit: mm)

T

Specifications and appearance of this unit as well as related 
products may be modified for improvement without prior 
notice.

General

Power / Voltage

: AC 24 V 50 Hz/60 Hz (Main Housing Unit)

Power Consumption

: 25 W (During heater operating, excluding 

camera)

Installation Location

: Outdoor (general)

Ambient Temperature

:

-

20 

I

 to 50 

 

I

(when equipped with 

TK-C676E, TK-C655E)

:

-

20 

I

 to 40 

I

 (when equipped with 

VN-C655U)

Heater Operation Temperature (Internal temperature)

: Heater turns ON between 8 

I

 ± 5 

I

Turns OFF between 20 

I

 ± 5 

I

Ambient Humidity : 35 % to 90 %

Vibration / Shock : Locations without vibration/shock

Dustproof / Waterproof

: IP66

T

When combined with compatible 
camera

Permissible Wind Speed

: 40 m/s or below

Mass: 

5.0 k

g

Accessories:

Instructions ...............................1

Desiccant..................................1

Screw (M4×20) .........................4

Hexagon wrench.......................1

Compatible Cameras: TK-C676E, TK-C655E, VN-C655U

Dimensional Outline Drawing (Unit: mm)

T

Specifications and appearance of this unit as well as related 
products may be modified for improvement without prior 
notice.

Specifications

WB-1540U

2

9

4

260

152
126

Ǟ

260

257

41

3

12

176

202

3

56

2-R4.

5

2-

R

7.75

2-

Ǟ

9

hole

WB-1550U

2

9

4

260

152
126

244

415

12

176

202

3

4

3

2-R4.5

Ǟ

260

2-

R

7.75

2-

Ǟ

9

hole

WB-1540_1550.book  Page 15  Thursday, May 17, 2007  3:21 PM

Содержание WB-1540U

Страница 1: ...NGLISH INSTRUCTIONS B WB 1550U only OUTDOOR HOUSING LST0267 001C WB 1540U WB 1550U For Customer Use Enter below the Serial No which is located on the body Retain this information for future reference Model No WB 1540U WB 1550U Serial No ...

Страница 2: ...attery power refer to the operating instructions 10 For added protection for this product during a lightning storm or when it is left unattended and unused for long periods of time unplug it from the wall outlet and disconnect the antenna or cable system This will prevent damage to the product due to lightning and power line surges 11 Do not allow anything to rest on the power cord Do not locate t...

Страница 3: ...s may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient ...

Страница 4: ...aler regarding installation and ensure that it is carried out by a specialist 䡵 Be sure to mount the safety wire for safety purposes If it falls it may cause injury or accidents 䡵 Taking vibrations mass and wind force into account ensure to mount in a location with sufficient strength using solid anchor bolts If reinforced or spiral nuts are not tightened enough picture blurring may occur on the m...

Страница 5: ...CLEAR HOME 7 4 1 8 0 5 2 9 6 3 ENTER AUTO PAN OPTION 1 OPTION 2 CAMERA POSI TION AUTO PATROL CLOSE NEAR WIDE AUTO F 1 F 2 F 3 PAN TILT LENS CAMERA POSITION CAMERA POSITION REMOTE CONTROL UNIT RM P2580 ALARM POWER KEY LOCK TO CAMERA LED1 TB1 AC24V INPUT WB 1540U WB 1550U WB 1540U WB 1550U Main Board To TB1 Fuse T To VIDEO OUT TO CCU Terminal To CONTROL ALARM IN OUT Terminal To Insulated AC 24 V Pow...

Страница 6: ...assembling the Housing 2 1 Main Housing Unit Screw A M4 x 6 x 3 Lower Housing Gasket Gasket Gland Screw B M4 x 6 Safety Wire CAUTION Pay careful attention to store the dismantled parts and screws until assembly is complete to prevent them from being misplaced Mounting the Camera TK C625U E 3 1 2 4 Interior of Housing Notch Camera Mounting Bracket Safety Wire Main Board AC 24 V Output Cable To POWE...

Страница 7: ...ount 3 Connect other cables Connect the necessary cables supplied with the housing coaxial video cable alarm signal cable LAN cable etc to the corresponding terminals on the ceiling mount 4 Mount the camera s ceiling mount to the main housing unit Use the 4 screws supplied M4 x 20 to mount the ceiling mount to the main housing unit 5 Mount the camera to the ceiling mount Follow instructions in the...

Страница 8: ...to left fig 3 Mount the safety wire and arm to the wall Mount the safety wire attached to the housing to the anchor bolts using the nut and wire Use the nut and wire to mount the housing onto the wall Assembling the Housing 1 2 3 Screw A M4 x 6 x 3 Gasket Gasket Gland Screw B M4 x 6 Lower Housing Main Housing Unit Desiccant Safety Wire Position Mark CAUTION Fogging may occur when there are drastic...

Страница 9: ...e the cable connection cover and fasten 4 screws M3 x 12 removed in step 4 using the provided hexagon wrench Mounting the Housing to the Wall continued 4 9 5 8 6 7 8 T Not in use on this system Bind using a waterproof adhesive tape Bind with insulating tape T DC 12 V Power Cable Alarm Communication Cable Coaxial Video Cable Hole Waterproofing Screw M3 x 12 x 4 AC 24 V Power Cable LAN Cable Male Wa...

Страница 10: ...rior of the combination camera A Turn the camera body cover in the direction as indicated in the left diagram When the camera body cover is tight and cannot be turned do so upon fastening the main unit B Dismantle the camera body cover C Dismantle the dome cover D Remove the rubber gasket and restore the dome cover and camera body cover to their original positions Disassembling the Housing 2 1 Saf...

Страница 11: ...amera TK C655E and TK C676E 1 2 3 4 Interior of Housing Notch Camera Mounting Bracket Safety Wire Main Board AC 24 V Output Cable To POWER INPUT AC 24 V Terminal of Ceiling Mount Cables F Mark Ceiling Mount ScrewsSupplied 4 pcs Camera JVC Mark CAUTION Connect the communication cable to the ALARM IN OUT and CONTROL terminals if necessary For safety reasons ensure to cut off any excess cable and bin...

Страница 12: ...18 V terminal of VN C655U s ceiling mount 3 Connect other cables Connect the necessary cables supplied with the housing coaxial video cable alarm signal cable LAN cable etc to the corresponding terminals on the ceiling mount 4 Mount the camera s ceiling mount to the main housing unit Use the screws supplied 4 pcs to mount the ceiling mount to the main housing unit 5 Mount the camera to the ceiling...

Страница 13: ...the safety wire and arm to the wall Mount the safety wire attached to the housing to the anchor bolts using the nut and wire Use the nut and wire to mount the housing onto the wall Assembling the Housing 3 2 1 Main Housing Unit Screw A M4 x 6 x 3 Lower Housing Gasket Screw B M4 x 8 Safety Wire Gasket Gland Desiccant Position Mark CAUTION Fogging may occur when there are drastic temperature changes...

Страница 14: ...cable connection is complete close the cable connection cover and fasten the 4 screws M3 x 12 removed in step 4 using the provided hexagon wrench Mounting the Housing to the Wall continued 4 9 5 6 7 8 8 Alarm Communication Cable Coaxial Video Cable AC 24 V Power Cable LAN Cable Male Screw M3 x 12 x 4 Bind using a waterproof adhesive tape Bind with insulating tape T Not in use on this system T DC 1...

Страница 15: ...rior notice 䡵 General Power Voltage AC 24 V 50 Hz 60 Hz Main Housing Unit Power Consumption 25 W During heater operating excluding camera Installation Location Outdoor general Ambient Temperature 20 I to 50 I when equipped with TK C676E TK C655E 20 I to 40 I when equipped with VN C655U Heater Operation Temperature Internal temperature Heater turns ON between 8 I 5 I Turns OFF between 20 I 5 I Ambi...

Страница 16: ... 2007 Victor Company of Japan Limited LST0267 001C WB 1540U WB 1550U OUTDOOR HOUSING ...

Отзывы: