-- 61 --
JVC VR-616
5.3.2 Alarm Link Setup
● Events : Select condition of Alarm Out.
Alarm inputs are 16EA and Alarm outputs are 4EA.
● Alarm Link Explanation
The above menu will display as checking Alarm Link button.
1) Alarm (left of the above picture) : Sets up which alarm will be output when alarm
occurs. Inputs are 1~16 and possible to select repeatedly.
2) Events (above of right) : Sets up events which will be output alarm signal. There are
Disk Full, Admin, PW Changed, Video Loss, and Motion. Possible to select
repeatedly.
3) Alarm Off (below of right) : How to off alarm when alarm occurred.
There are Manual and Auto.
4) Alarm Output Number : The part for selecting output port when signal is in
according to alarm and event setup. Output ports are in rear of product and able to
select one of them.
5) Alarm in/out ports are in rear of product there are 16pcs of input ports and 4pcs of
output ports.
Move to previous menu after finish setup by using EXIT button.
Alarm output number
Present output number is 1
5.3.2.1 Alarm
Moves by using ▲, ▼ buttons or Jog.
Displays alarmed channel. For selecting channel you want to detect, press ENTER
button after moving cursor to detect. Canceling is the same way.