2. Connecting to a network
Turn on the power of only one VN-C3U unit.
When network connection is completed and the power is turned on, the
VN-C3U unit will be connected to the network at the following IP address.
Factory set (Default) IP address 192. 168. 0. 2
●
About the power supply connection cable
• Length: 30m or less.
• Recommended model: UL1007, UL1015 or equivalent cable with wire
equivalent to ID AWG #20 or larger.
Caution
All VN-C3U units are set to the same IP address at the factory; therefore,
if the power of multiple VN-C3U units is turned on at the same time, address
duplication will occur and correct access will not be possible. Always turn
the power on for only one unit at a time. If address duplication occurred,
perform the proper processing and wait for 10 min. or more, or turn off the
power of all units on the network and then turn the power on again;
otherwise, correct access may not be possible.
10BASE-T
DC12V
–
+
10 BASE-T cable
12VDC
power supply
❉
Use a straight cable when
connecting to a hub.
Use a cross cable when
connecting directly to a PC.
Power supply connection cable
VM-C3U̲E.65J