background image

Camera Settings 

Network Interface 

If the camera does not have a native ethernetport 
directly on the camera body, a USB/Ethernet 
adapter must be utilized from the USB2.0 HOST 
port.  

Authentication 

Web access 

must

 be enabled on the camera with  

Login Name: jvc 
Login Password: skaarhoj 

In order for the controllers to authenticate with the 
cameras. The above login name and login 
password are set by default on the controllers. 
Please consult the camera manual for instructions 
in setting web access. 

IP settings 

A static IP address must be set on the camera  
Please consult the camera manual for instructions. 

Firmware 

The JVC GY- HC900 must have the firmware 
version 

v0230-0217

 or newer.  

The JVC GY HC550 must have the firmware 
version 

v0120-0166

 or newer 

9

Содержание RM-LP250M

Страница 1: ...JVC Connected Cam Studio RCP RM LP250S RM LP250M USER GUIDE March 2020 Get the latest version of this User Guide at https www skaarhoj com support manuals 1 ...

Страница 2: ...k Interface 9 Authentication 9 IP settings 9 Firmware 9 Controller Settings 10 IP Settings 10 Firmware Update 10 DB9 EXT I O 10 Network Interface Details 11 Power over Ethernet PoE Specifications 11 Troubleshooting 11 Controller Use 12 RM LP250S 12 RM LP250M 14 Parameter Settings 15 Dimensions 16 Changing Default Configuration 17 Different Mapping of Functions 17 Changing Default Username Password fo...

Страница 3: ...Maintenance Precautions If there is dust on the controller and the displays remove the dust gently using a oil free brush or dust blowing apparatus Do not use organic solvents such as benzene or ethanol when cleaning the surface of the controller Regulatory Compliance For private households Information on Disposal for Users of WEEE This symbol on the product s and or accompanying documents means t...

Страница 4: ...cter Output Mix Super crisp window with large display tiles for settings High quality encoders with RGB backlight for function identification Camera ID display with OLED technology RGB tally bar Preview button for GPI or control of video router Four way buttons with OLED legends for dynamic labelling and functionality Pressure and direction sensitive joystick pad Master black knob with dedicated O...

Страница 5: ...ion 4 Elastomer joypad 5 Group of 6 4 way buttons with associated displays 6 Recording streaming buttons with associated display 7 Camera ID display 8 Master black encoder with associated display 9 Tally bar 10 Shift and system status 11 Joystick with master black ring and push button 12 Iris control parameters 13 4 way button for Preview 5 CONNECTED CAM STUDIO 1 2 3 4 5 6 7 9 8 10 11 12 13 ...

Страница 6: ...ntification 4 Elastomer joypad 5 Group of 6 4 way buttons with associated displays 6 Recording streaming buttons with associated display 7 Camera ID display 8 Master black encoder with associated display 9 Tally bar 10 Shift and system status 11 Iris wheel 12 Iris control parameters 13 4 way button for Preview 6 CONNECTED CAM STUDIO 1 2 3 4 5 6 7 9 8 10 11 12 13 ...

Страница 7: ...settings only 4 IP Network RJ45 Port For IP Control with PoE 48V IEEE 802 3af 5 12V DC Power Supply Connect the supplied DC Power adaptor 6 Status LED For monitoring and debugging 7 Reset button Controller reset same as taking the power of the controller 8 Programming mode reset Only to be used if contact with support have been established 7 0 8 4 C 1 2 3 5 6 7 9A B D E F 2 4 5 7 8 1 6 3 ...

Страница 8: ...S is designed to control one camera The RM LP250M is designed to control up to 3 cameras at the same time Power Use only the DC power adapter supplied with the controller Do not use any other DC power adaptor If using PoE to power the controller make sure the network switch supports PoE 48V IEEE 802 3af Ensure the PoE provider has sufficient power budget to power the controller Otherwise it will n...

Страница 9: ...aarhoj In order for the controllers to authenticate with the cameras The above login name and login password are set by default on the controllers Please consult the camera manual for instructions in setting web access IP settings A static IP address must be set on the camera Please consult the camera manual for instructions Firmware The JVC GY HC900 must have the firmware version v0230 0217 or ne...

Страница 10: ... same subnet Avoid having Device Cores activated which does not connect to an actual camera Firmware Update 1 Download and install the Firmware Updater Application 2 Connect the USB cable to the controller and to the computer Power the controller 3 Press Check for Updates This generates a new firmware file and downloads it to the controller It will reboot once completed DB9 EXT I O This is the pin...

Страница 11: ...roller using PoE it is important the network switch supports this standard Please notice some manufactures such as Ubiquity have their own non standard 24V type of PoE which is incompatible with the controller Especially pay attention to the standard if using a PoE injector Troubleshooting If experiencing no network activity at all try one or more of the following suggestions Use a managed network...

Страница 12: ... on the camera via other systems via the B13 button Black Controls Master Black Menu WB Sh Menu Lens K1 WB Paint Red Focus K2 WB Paint Blue Focus One Push K3 WB Mode Focus Mode K4 WB One Push Press and hold to activate Detail K5 Full Auto Iris Mode K6 Gain Mode Iris K7 Shutter Mode Iris One Push K8 Shutter Speed AE Level Shift Off Shift On M1 Sets Menu WB Sh Sets Menu WB Sh M2 Sets Menu Lens Sets ...

Страница 13: ...signed to the joystick ring The camera protocol does not support setting an absolute value for Master Black Button Activates Preview relay on DB9 connector B13 Shift Off Shift On B9 Active Panel If enabled no hardware interface will respond Iris Range Reset Points B10 Iris one Push Iris Range Set fully open B11 Iris Mode Light up Red when in Auto Green when in manual Iris Range Set fully closed Sh...

Страница 14: ...lly on the cameras are set by other systems or if tally have been enabled via button B13 Black Controls Master Black Menu WB Sh Menu Lens K1 WB Paint Red Focus K2 WB Paint Blue Focus One Push K3 WB Mode Focus Mode K4 WB One Push Press and hold to activate Detail K5 Full Auto Iris Mode K6 Gain Mode Iris K7 Shutter Mode Iris One Push K8 Shutter Speed AE Level Shift Off Shift On M1 Sets Menu WB Sh Se...

Страница 15: ... Parameter Settings When changing a parameter the icon illustrated below will appear This indicates that communication is being sent to the camera which the camera is currently processing This method have been adopted to accommodate how the protocol between the controller and the cameras work Shift Off Shift On B13 Upper Edge hold down Hijacks main display to show actions for C1 C8 Lower Edge hold...

Страница 16: ...Dimensions 16 CONNECTED CAM STUDIO 35 5 cm 10 2 cm Not to scale 4 7 cm 7 2 cm 2 3 cm 6 0 cm 24 6 cm 11 9 cm 2 3 cm Thickness 0 3 cm Not to scale ...

Страница 17: ...nality on the diffrent hardware components on the controller This is presented in the following section If one would like to change the default username and password for authentication please see Changing Default Username Password for Authentication Different Mapping of Functions Coming soon 17 ...

Страница 18: ... for RM LP250M D0 0 jvc D0 1 skaarhoj D0 2 80 D1 0 jvc D1 1 skaarhoj D1 2 80 D2 0 jvc D2 1 skaarhoj D2 2 80 Example 1 Setting username password could look like this device configuration code in the generic form D0 0 Username D0 1 Password A example could be D0 0 bryan D0 1 1234567 Where username is set to bryan and password set to 1234567 The general form of Device Core options are Dx y z where x ...

Страница 19: ...uration page for your controller on cores skaarhoj com Example 2 Setting port could look like this device configuration code in the generic form D0 2 12345 To confirm that a device configuration is in fact detected by the controller please check it out on the serial monitor where it will be mentioned 19 ...

Страница 20: ...Serial Monitor during the bootup would displays Successfully recalled Limit 0 and lowr 0 At location 0 And not the number 255 iris in the LED Bar will not be shown The iris range limitation is used to set a range for the joystick on the RM LP250S In order to resolve this the action Iris Range Reset point must be triggered for the impacted Device Cores 20 ...

Страница 21: ... following actions JVC RCP Iris Range Reset points JVC RCP 2 Iris Range Reset points JVC RCP 3 Iris Range Reset points Press Save and then press C1 button on the RM LP250M Once completed open the Serial Monitor in the Firmware Application and press Clear Presets This will remove the actions just assigned to C1 and local IP settings as well 21 ...

Отзывы: