background image

Important Information 

Legal Notice 

Attention:

 

The content and instructions of this document are 
subject to change without prior notice. Updates 
will be added to the manual. 

Best effort have been conducted to verify the 
correctness of the content in this manual, but no 
statement, information, or recommendation in this 
manual shall constitute formal guarantee of any 
kind, expressed or implied. We shall not be held 
responsible for any technical or typographical 
error in this manual. 

The product and graphic appearance 
demonstrated in this manual is for reference only, 
and may differ from the actual appearance of your 
device and associated software applications.  

Use of this manual and the subsequent result shall 
be entirely on the user’s own responsibility.  

Reference to product names of other companies 
in this manual are the trademark or registered 
trademark of the respective companies.  

Warnings 

• If the product does not work properly, please 

contact your dealer. Never attempt to 
disassemble the controller yourself (we will not 
assume any responsibility for problems caused 
by unauthorized repair or maintenance) 

• This installation should be made by a qualified 

service person and should conform to all the 
local codes  

• When shipping, the controller should be packed 

in its original packaging 

• Make sure the power supply voltage is correct 

before using the controller 

• Do not drop the controller or subject it to 

physical shock 

Maintenance Precautions 

• If there is dust on the controller and the 

displays, remove the dust gently using a oil-free 
brush or dust blowing apparatus  

• Do not use organic solvents, such as benzene or 

ethanol when cleaning the surface of the 
controller 

Regulatory Compliance 

For private households: Information on 
Disposal for Users of WEEE  

This symbol on the product(s) 
and / or accompanying documents 
means that used electrical and 
electronic equipment (WEEE) 
should not be mixed with general 
household waste. For proper 
treatment, recovery and recycling, please take this 
product(s) to designated collection points where 
it will be accepted free of charge.  

Alternatively, in some countries, you may be able 
to return your products to your local retailer upon 
purchase of an equivalent new product.  

Disposing of this product correctly will help save 
valuable resources and prevent any potential 
negative effects on human health and the 
environment, which could otherwise arise from 
inappropriate waste handling.  

Please contact your local authority for further 
details of your nearest designated collection 
point.  

Penalties may be applicable for incorrect disposal 
of this waste, in accordance with you national 
legislation. 

For professional users in the European Union 

 

If you wish to discard electrical and electronic 
equipment (EEE), please contact your dealer or 
supplier for further information. 

For disposal in countries outside of the 
European Union 

 

This symbol is only valid in the European Union 
(EU). If you wish to discard this product please 
contact your local authorities or dealer and ask for 
the correct method of disposal. 

3

Figure 1

Содержание RM-LP250M

Страница 1: ...JVC Connected Cam Studio RCP RM LP250S RM LP250M USER GUIDE March 2020 Get the latest version of this User Guide at https www skaarhoj com support manuals 1 ...

Страница 2: ...k Interface 9 Authentication 9 IP settings 9 Firmware 9 Controller Settings 10 IP Settings 10 Firmware Update 10 DB9 EXT I O 10 Network Interface Details 11 Power over Ethernet PoE Specifications 11 Troubleshooting 11 Controller Use 12 RM LP250S 12 RM LP250M 14 Parameter Settings 15 Dimensions 16 Changing Default Configuration 17 Different Mapping of Functions 17 Changing Default Username Password fo...

Страница 3: ...Maintenance Precautions If there is dust on the controller and the displays remove the dust gently using a oil free brush or dust blowing apparatus Do not use organic solvents such as benzene or ethanol when cleaning the surface of the controller Regulatory Compliance For private households Information on Disposal for Users of WEEE This symbol on the product s and or accompanying documents means t...

Страница 4: ...cter Output Mix Super crisp window with large display tiles for settings High quality encoders with RGB backlight for function identification Camera ID display with OLED technology RGB tally bar Preview button for GPI or control of video router Four way buttons with OLED legends for dynamic labelling and functionality Pressure and direction sensitive joystick pad Master black knob with dedicated O...

Страница 5: ...ion 4 Elastomer joypad 5 Group of 6 4 way buttons with associated displays 6 Recording streaming buttons with associated display 7 Camera ID display 8 Master black encoder with associated display 9 Tally bar 10 Shift and system status 11 Joystick with master black ring and push button 12 Iris control parameters 13 4 way button for Preview 5 CONNECTED CAM STUDIO 1 2 3 4 5 6 7 9 8 10 11 12 13 ...

Страница 6: ...ntification 4 Elastomer joypad 5 Group of 6 4 way buttons with associated displays 6 Recording streaming buttons with associated display 7 Camera ID display 8 Master black encoder with associated display 9 Tally bar 10 Shift and system status 11 Iris wheel 12 Iris control parameters 13 4 way button for Preview 6 CONNECTED CAM STUDIO 1 2 3 4 5 6 7 9 8 10 11 12 13 ...

Страница 7: ...settings only 4 IP Network RJ45 Port For IP Control with PoE 48V IEEE 802 3af 5 12V DC Power Supply Connect the supplied DC Power adaptor 6 Status LED For monitoring and debugging 7 Reset button Controller reset same as taking the power of the controller 8 Programming mode reset Only to be used if contact with support have been established 7 0 8 4 C 1 2 3 5 6 7 9A B D E F 2 4 5 7 8 1 6 3 ...

Страница 8: ...S is designed to control one camera The RM LP250M is designed to control up to 3 cameras at the same time Power Use only the DC power adapter supplied with the controller Do not use any other DC power adaptor If using PoE to power the controller make sure the network switch supports PoE 48V IEEE 802 3af Ensure the PoE provider has sufficient power budget to power the controller Otherwise it will n...

Страница 9: ...aarhoj In order for the controllers to authenticate with the cameras The above login name and login password are set by default on the controllers Please consult the camera manual for instructions in setting web access IP settings A static IP address must be set on the camera Please consult the camera manual for instructions Firmware The JVC GY HC900 must have the firmware version v0230 0217 or ne...

Страница 10: ... same subnet Avoid having Device Cores activated which does not connect to an actual camera Firmware Update 1 Download and install the Firmware Updater Application 2 Connect the USB cable to the controller and to the computer Power the controller 3 Press Check for Updates This generates a new firmware file and downloads it to the controller It will reboot once completed DB9 EXT I O This is the pin...

Страница 11: ...roller using PoE it is important the network switch supports this standard Please notice some manufactures such as Ubiquity have their own non standard 24V type of PoE which is incompatible with the controller Especially pay attention to the standard if using a PoE injector Troubleshooting If experiencing no network activity at all try one or more of the following suggestions Use a managed network...

Страница 12: ... on the camera via other systems via the B13 button Black Controls Master Black Menu WB Sh Menu Lens K1 WB Paint Red Focus K2 WB Paint Blue Focus One Push K3 WB Mode Focus Mode K4 WB One Push Press and hold to activate Detail K5 Full Auto Iris Mode K6 Gain Mode Iris K7 Shutter Mode Iris One Push K8 Shutter Speed AE Level Shift Off Shift On M1 Sets Menu WB Sh Sets Menu WB Sh M2 Sets Menu Lens Sets ...

Страница 13: ...signed to the joystick ring The camera protocol does not support setting an absolute value for Master Black Button Activates Preview relay on DB9 connector B13 Shift Off Shift On B9 Active Panel If enabled no hardware interface will respond Iris Range Reset Points B10 Iris one Push Iris Range Set fully open B11 Iris Mode Light up Red when in Auto Green when in manual Iris Range Set fully closed Sh...

Страница 14: ...lly on the cameras are set by other systems or if tally have been enabled via button B13 Black Controls Master Black Menu WB Sh Menu Lens K1 WB Paint Red Focus K2 WB Paint Blue Focus One Push K3 WB Mode Focus Mode K4 WB One Push Press and hold to activate Detail K5 Full Auto Iris Mode K6 Gain Mode Iris K7 Shutter Mode Iris One Push K8 Shutter Speed AE Level Shift Off Shift On M1 Sets Menu WB Sh Se...

Страница 15: ... Parameter Settings When changing a parameter the icon illustrated below will appear This indicates that communication is being sent to the camera which the camera is currently processing This method have been adopted to accommodate how the protocol between the controller and the cameras work Shift Off Shift On B13 Upper Edge hold down Hijacks main display to show actions for C1 C8 Lower Edge hold...

Страница 16: ...Dimensions 16 CONNECTED CAM STUDIO 35 5 cm 10 2 cm Not to scale 4 7 cm 7 2 cm 2 3 cm 6 0 cm 24 6 cm 11 9 cm 2 3 cm Thickness 0 3 cm Not to scale ...

Страница 17: ...nality on the diffrent hardware components on the controller This is presented in the following section If one would like to change the default username and password for authentication please see Changing Default Username Password for Authentication Different Mapping of Functions Coming soon 17 ...

Страница 18: ... for RM LP250M D0 0 jvc D0 1 skaarhoj D0 2 80 D1 0 jvc D1 1 skaarhoj D1 2 80 D2 0 jvc D2 1 skaarhoj D2 2 80 Example 1 Setting username password could look like this device configuration code in the generic form D0 0 Username D0 1 Password A example could be D0 0 bryan D0 1 1234567 Where username is set to bryan and password set to 1234567 The general form of Device Core options are Dx y z where x ...

Страница 19: ...uration page for your controller on cores skaarhoj com Example 2 Setting port could look like this device configuration code in the generic form D0 2 12345 To confirm that a device configuration is in fact detected by the controller please check it out on the serial monitor where it will be mentioned 19 ...

Страница 20: ...Serial Monitor during the bootup would displays Successfully recalled Limit 0 and lowr 0 At location 0 And not the number 255 iris in the LED Bar will not be shown The iris range limitation is used to set a range for the joystick on the RM LP250S In order to resolve this the action Iris Range Reset point must be triggered for the impacted Device Cores 20 ...

Страница 21: ... following actions JVC RCP Iris Range Reset points JVC RCP 2 Iris Range Reset points JVC RCP 3 Iris Range Reset points Press Save and then press C1 button on the RM LP250M Once completed open the Serial Monitor in the Firmware Application and press Clear Presets This will remove the actions just assigned to C1 and local IP settings as well 21 ...