MX-J570V/MX-J680V
1-32
Items
Measurement
conditions
Measurement method
Standard
values
Adjusting
positions
1.With the recording and playback mechanism,
load the test tapes(AC-514 to TYP
and AC-225 to
TYP
),and set the mechanism to the recording and
pausing conditions in advance.
2.After connecting 100
in series to the recorder
head,measure the bias current with a valve
voltmeter at both of the terminals.
3.After resetting the [PAUSE] mode,start recording.
At this time,adjust VR101 for LcH and VR201 for
RcH so that the recording bias current values
become 4.0
A (TYP
) and 4.20
A(TYP
).
1.With the recording and playback mechanism,load
the test tape(AC-514 to TYP
),and set the
mechanism to the recording and pausing condition
in advance.
2.While repetitively inputting the reference frequency
signal of 1kHz and 10kHz from OSC IN, record and
playback the test tape.
3.While recording and playing back the test tape in
TYP
,adjust VR101 for LcH and VR201 for RcH
so that the output deviation between 1kHz and
10kHz becomes -1dB
2dB.
Adjustment of
recording bias
current
(Reference
value)
Adjustment of
recording and
playback
frequency
characteristics
*Mode : Forward or
reverse mode
*Recording mode
*Test tape
:AC-514 and AC-225
Measurement output
terminal
:Both recording and
headphone terminals
Reference frequency
:1kHz and 10kHz
(REF:-20dB)
Test tape
:TYP
AC-514
Measurement input
terminal
:OSC IN
AC-225
:4.20
A
AC-514
:4.0
A
Output
deviation
between
1kHz and
10kH
:-1dB
2dB
LcH
:VR101
RcH
:VR201
LcH
:VR101
RcH
:VR201
Electrical performance
Items
Measurement
conditions
Measurement method
Standard
values
Adjusting
positions
1.While changing over to and from BIAS 1 and 2,
confirm that the frequency is changed.
2.With the recording and playback mechanism.
load the test tape (AC-514 to TYP
),and set the
mechanism to the recording and pausing
conditions in advance.
3.Confirm that the BIAS TP frequency on the
P.C.board is 100kHz
6kHz.
1.With the recording and playback mechanism,
load the test tapes(AC-514 to TYP
and AC-225
to TYP
),and set the mechanism to the recording
and pausing condition in advance.
2.After setting to the recording conditions,connect
1M
in series to the eraser head on the recording
and playback mechanism side,and measure the
eraser current from both of the eraser terminal.
Recording
bias frequency
Eraser current
(Reference
value)
*Recording and
playback side forward
or reverse
*Test tape
:TYP
AC-514
*Measurement
terminal BIAS TP on
P.C.board
*Recording and
playback side forward
or reverse
*Recording mode
*Test tape
:AC-514 and AC-225
Measurement terminal
Both of the eraser
head
100kHz
+9kHz
-7kHz
TYP
:120mA
TYP
:75mA
Reference values for electrical function confirmation items
Содержание MX-J570V
Страница 64: ...MX J570V MX J680V 1 64 MEMO ...
Страница 77: ...H A B C D E F G 2 12 MX J570V MX J680V n pre amplifier board ted circuit boards ...
Страница 78: ...A B C D E F G 2 13 MX J570V MX J680V Power supplly input output board ...
Страница 81: ...A B C D 1 2 3 4 5 MX J570V MX J680V 2 16 VCD board ...
Страница 82: ...A B C 1 2 3 4 5 MX J570V MX J680V 2 17 Head amplifier board ...
Страница 83: ...A B C D 1 2 3 4 5 MX J570V MX J680V 2 18 Tuner board ...
Страница 95: ...A B C D 1 2 3 4 5 MX J570V MX J680V 3 12 4 1 6 30 12 10 3 B mecha A mecha ...