UX-M55
1-11
Fig.22
Claw
g
Disengage the cassette
torsion spring so that it
comes to the front of the
claw
g
.
Front cabinet assembly
Cassette torsion spring
Technical door
Fig.23
AA
Front cabinet assembly
Arm section
h
Arm section
j
Shaft section
i
Cassette torsion spring
Shaft section
k
Logic deck bracket
Technical door
1.
2.
3.
4.
5.
Open the technical door, disengage the cassette
torsion spring hooked across the front of the front
cabinet assembly and the technical door in the
outward direction, and remove it from the claw
g
.
(See Fig.22.)
From the back side of the front cabinet assembly,
remove the two screws
AA
retaining the logic
deck bracket. (See Fig.23.)
While pushing the arm section
h
of the technical
door in the direction of the arrow, remove the shaft
section
i
of the technical door from the front
cabinet assembly. (See Fig.23.)
While pushing the arm section
j
of the technical
door in the direction of the arrow, remove the shaft
section
k
of the technical door from the front
cabinet assembly. (See Fig.23.)
Take out the technical door from the back side of
the front cabinet assembly.
Remove the cassette mechanism assembly.
Remove the cassette door cover.
[Caution] In the assembly, be sure to put the
cassette torsion spring around
the shaft section i before attaching
the technical door.
Removing the technical door
(See Figs. 22 and 23.)
[Note] After assembly, apply a locking agent
to the screws AA.