(No.YA509)2-1
STANDARD CIRCUIT DIAGRAM
NOTE ON USING CIRCUIT DIAGRAMS
5.NOTE FOR REPAIRING SERVICE
This model's power circuit is partly different in the GND. The
difference of the GND is shown by the LIVE : ( ) side GND and the
ISOLATED(NEUTRAL) : ( ) side GND. Therefore, care must be
taken for the following points.
(1)Do not touch the LIVE side GND or the LIVE side GND and the
ISOLATED(NEUTRAL) side GND simultaneously. if the above
caution is not respected, an electric shock may be caused.
Therefore, make sure that the power cord is surely removed from
the receptacle when, for example, the chassis is pulled out.
(2)Do not short between the LIVE side GND and ISOLATED(NEUTRAL)
side GND or never measure with a measuring apparatus measure
with a measuring apparatus ( oscilloscope, etc.) the LIVE side GND
and ISOLATED(NEUTRAL) side GND at the same time.
If the above precaution is not respected, a fuse or any parts will be broken.
Since the circuit diagram is a standard one, the circuit and
circuit constants may be subject to change for improvement
without any notice.
NOTE
Due improvement in performance, some part numbers show
in the circuit diagram may not agree with those indicated in
the part list.
When ordering parts, please use the numbers that appear
in the Parts List.
(7)Ground symbol
: LIVE side ground
: ISOLATED(NEUTRAL) side ground
: EARTH ground
: DIGITAL ground
(6)Connecting method
: Connector
: Wrapping or soldering
: Receptacle
(5)Test point
: Test point
: Only test point display
Respective voltage values are indicated
: B1
: 9V
: 5V
: B2 (12V)
(4)Power Supply
Type
MM
: Metalized mylar capacitor
PP
: Polypropylene capacitor
MPP
: Metalized polypropylene capacitor
MF
: Metalized film capacitor
TF
: Thin film capacitor
BP
: Bipolar electrolytic capacitor
TAN
: Tantalum capacitor
(3)Coils
No unit
Others
: [µH]
: As specified
No indication
: Ceramic capacitor
(2)Capacitors
Capacitance value
1 or higher
: [pF]
less than 1
: [µF]
Withstand voltage
No indication
: DC50[V]
Others
: DC withstand voltage [V]
AC indicated
: AC withstand voltage [V]
Electrolytic Capacitors
47/50[Example]: Capacitance value [µF]/withstand voltage[V]
Composition resistor 1/2 [W] is specified as 1/2S or Comp.
Type
No indication
: Carbon resistor
OMR
: Oxide metal film resistor
MFR
: Metal film resistor
MPR
: Metal plate resistor
UNFR
: Uninflammable resistor
FR
: Fusible resistor
4.INDICATIONS ON THE CIRCUIT DIAGRAM
(1)Resistors
Resistance value
No unit
: [
Ω
]
K
: [k
Ω
]
M
Rated allowable power
No indication
: 1/16 [W]
Others
: As specified
: [M
Ω
]
3.INDICATION OF PARTS SYMBOL [EXAMPLE]
In the PW board
: R209
R209
1.SAFETY
The components identified by the
symbol and shading are
critical for safety. For continued safety replace safety ciritical
components only with manufactures recommended parts.
Since the voltage values of signal circuit vary to some extent
according to adjustments, use them as reference values.
2.SPECIFIED VOLTAGE AND WAVEFORM VALUES
The voltage and waveform values have been measured under the
following conditions.
(1)Input signal
: Colour bar signal
(2)Setting positions of
each knob/button and
variable resistor
(3)Internal resistance of tester
: DC 20k
Ω
/V
(4)Oscilloscope sweeping time
: H
20µs / div
: V
5ms / div
: Othters
Sweeping time is
specified
(5)Voltage values
: All DC voltage values
: Original setting position
when shipped
LT-26A80SU
,
LT-26A80ZU
,
LT-26DA8BJ, LT-26DA8SJ
,
LT-26DA8SU
,
LT-26DA8ZU
,
LT-26DT8ZJ
,
LT-32A80SU
,
LT-32A80ZU
,
LT-32DA8BJ
,
LT-32DA8SJ
,
LT-32DA8SU,
LT-32DA8ZU
,
LT-32DT8ZJ