background image

(No.MA511<Rev.001>)4/16

SECTION 1

PRECAUTION

1.1

Safety Precautions

(1) This design of this product contains special hardware and

many circuits and components specially for safety  purpos-
es. For continued protection, no changes should be made
to the original design unless authorized in writing by the
manufacturer. Replacement parts must be identical to
those used in the original circuits. Services should be per-
formed by qualified personnel only.

(2) Alterations of the design or circuitry of the product should

not be made. Any design alterations of the product should
not be made. Any design alterations or additions will void
the manufacturers warranty and will further relieve the
manufacture of responsibility for personal injury or property
damage resulting therefrom.

(3) Many electrical and mechanical parts in the products have

special safety-related characteristics. These characteris-
tics are often not evident from visual inspection nor can the
protection afforded by them necessarily be obtained by us-
ing replacement components rated for higher voltage, watt-
age, etc. Replacement parts which  have these special
safety characteristics are identified in the Parts List of Ser-
vice Manual. Electrical components having such features
are identified by shading on the schematics and by (   ) on
the Parts List in the Service Manual. The use of a substitute
replacement which does not have the same safety charac-
teristics as the recommended replacement parts shown in
the Parts List of Service Manual may create shock, fire, or
other hazards.

(4) The leads in the products are routed and dressed with ties,

clamps, tubings, barriers and the like to be separated from
live parts, high temperature parts, moving parts and/or
sharp edges for the prevention of electric shock and fire
hazard. When service is required, the original lead routing
and dress should be observed, and it should be confirmed
that they have been returned to normal, after reassem-
bling.

(5) Leakage shock hazard testing

After reassembling the product, always perform an isola-
tion check on the exposed metal parts of the product (an-
tenna terminals, knobs, metal cabinet, screw heads,
headphone jack, control shafts, etc.) to be sure the product
is safe to operate without danger of electrical shock.Do not
use a line isolation transformer during this check.
• Plug the AC line cord directly into the AC outlet. Using a

"Leakage Current Tester", measure the leakage  current
from each exposed metal parts of the cabinet, particular-
ly any exposed metal part having a return path to the
chassis, to a known good earth ground. Any leakage cur-
rent must not exceed 0.5mA AC (r.m.s.).

• Alternate check method

Plug the AC line cord directly into the AC outlet. Use an
AC voltmeter having, 1,000

 per volt or more sensitivity

in the following manner. Connect a 1,500

 10W resistor

paralleled by a 0.15

µ

F AC-type capacitor between an ex-

posed metal part and a known good earth ground.
Measure the AC voltage across the resistor with the AC

voltmeter. 
Move the resistor connection to each exposed metal
part, particularly any exposed metal part having a return
path to the chassis, and measure the AC voltage across
the resistor. Now, reverse the plug in the AC outlet and
repeat each measurement. Voltage measured any must
not exceed 0.75 V AC (r.m.s.). This corresponds to  0.5
mA AC (r.m.s.). 

1.2

Warning

(1) This equipment has been designed and manufactured to

meet international safety standards.

(2) It is the legal responsibility of the repairer to ensure that

these safety standards are maintained.

(3) Repairs must be made in accordance with the relevant

safety standards.

(4) It is essential that safety critical components are replaced

by approved parts.

(5) If mains voltage selector is provided, check setting for local

voltage.

1.3

Caution

Burrs formed during molding may be left over on some parts
of the chassis. 
Therefore, pay attention to such burrs in the case of pre-
forming repair of this system.

1.4

Critical parts for safety

In regard with component parts appearing on the silk-screen
printed side (parts side) of the PWB diagrams, the parts that are
printed over with black such as the resistor ( 

 ), diode ( 

 )

and ICP ( 

 ) or identified by the "   " mark nearby are critical

for safety.  When replacing them, be sure to use the parts of the
same type and rating as specified by the manufacturer. 
(This regulation dose not Except the J and C version)

Good earth ground

Place this 
probe on 
each exposed
metal part.

AC VOLTMETER
(Having 1000 
ohms/volts,
or more sensitivity)

1500     10W

0.15   F  AC TYPE

Содержание KD-SD631E

Страница 1: ...OPYRIGHT 2011 JVC KENWOOD Corporation Lead free solder used in the board material Sn Ag Cu melting point 219 Centigrade Lead free solder used in the board material Sn Cu melting point 230 Centigrade DETACH PANEL KD SD631E KD SD631EN KD SD631EY KD SD636U KD SD636UN KD SD636UT KD SD636UP KD SD637EE CP SD631ED CP SD631ED CP SD631ED CP SD636UD CP SD636UD CP SD636UD CP SD636UD CP SD637EED Model Parts n...

Страница 2: ...uency Range 531 kHz to 1 611 kHz Sensitivity Selectivity 20 µV 40 dB CD PLAYER SECTION Signal Detection System Non contact optical pickup semiconductor laser Number of Channels 2 channels stereo Frequency Response 5 Hz to 20 000 Hz Signal to Noise Ratio 98 dB Wow and Flutter Less than measurable limit USB SECTION USB Standard USB 1 1 USB 2 0 Data Transfer Rate Full Speed Max 12 Mbps Compatible Dev...

Страница 3: ...1 kHz to 1 611 kHz LW 153 kHz to 279 kHz Sensitivity Selectivity MW 20 µV 40 dB LW 50 µV CD PLAYER SECTION Signal Detection System Non contact optical pickup semiconductor laser Number of Channels 2 channels stereo Frequency Response 5 Hz to 20 000 Hz Signal to Noise Ratio 98 dB Wow and Flutter Less than measurable limit USB SECTION USB Standard USB 1 1 USB 2 0 Data Transfer Rate Full Speed Max 12...

Страница 4: ...one jack control shafts etc to be sure the product is safe to operate without danger of electrical shock Do not use a line isolation transformer during this check Plug the AC line cord directly into the AC outlet Using a Leakage Current Tester measure the leakage current from each exposed metal parts of the cabinet particular ly any exposed metal part having a return path to the chassis to a known...

Страница 5: ... to check the condition of the laser diode in the optical pickup The tester s internal power source can easily destroy the laser diode 1 6 Handling the traverse unit optical pickup 1 Do not subject the traverse unit optical pickup to strong shocks as it is a sensitive complex unit 2 Cut off the shorted part of the flexible cable using nippers etc after replacing the optical pickup For specific det...

Страница 6: ...his laser product uses visible and or invisible laser radiation and is equipped with safety switches which prevent emission of radiation when the drawer is open and the safety interlocks have failed or are defeated It is dangerous to defeat the safety switches 5 CAUTION If safety switches malfunction the laser is able to function 6 CAUTION Use of controls adjustments or performance of procedures o...

Страница 7: ... Fig 1 3 1 2 Removing the Front chassis See Fig 2 1 Disengage the 4 hooks b engaging both sides of the Front chassis Fig 2 3 1 3 Removing the Erectric unit See Fig 3 4 and 6 1 Remove the 1 screw A attaching the Rear bracket See Fig 3 Fig 3 2 Remove the 2 screws B attaching both sides of the Top chassis See Fig 4 Fig 4 3 Remove the 3 screws C attaching the Main board See Fig 5 Fig 5 4 Disconnect th...

Страница 8: ... 8 3 2 CD mechanism assembly section 3 2 1 Removing the Mecha control board 1 Solder the short land on the pickup See Fig 1 Fig 1 2 Remove the 8 wires from the Mecha control board See Fig 2 Fig 2 3 Disconnect the flexible wire from the pickup connected to the connector CN102 on the Mecha control board See Fig 3 4 Remove the 2 screws A attaching the Mecha control board See Fig 3 Fig 3 D D D E E E E...

Страница 9: ...rame assembly See Fig 5 Fig 5 3 2 3 Removing the Pickup See Fig 6 7 1 Remove the 2 screws C attaching the feed bracket assem bly See Fig 6 Fig 6 2 Remove the shaft from the TM base See Fig 7 3 Disengage the hook a on the pickup from the TM base See Fig 7 Fig 7 3 2 4 Removing the Spindle motor See Fig 8 9 1 Remove the HC CL Spring from the HC CL base and the TM base and then lift up the HC CL base ...

Страница 10: ... attaching the spindle motor See Fig 10 Fig 10 3 2 5 Removing the Loading motor 1 Remove the roller arm assembly from the bottom frame as sembly See Fig 11 Fig 11 2 Remove the 2 screws E attaching the loading motor as sembly and then remove the loading motor assembly in the direction of the arrow See Fig 12 Fig 12 D E ...

Страница 11: ...1 hour the display is indicated per 10 minutes 00001 10922 are displayed in XXXXX MAX 10922 hours DOWN Disc operation duration display 00 50 are displayed in X X For less than 1 hour the display is indicated per 10 minutes 00001 10922 are displayed in XXXXX MAX 10922 hours BRIGHTNESS TAG iPod SD Disc eject number of times 00001 99999 are displayed in XXXXX BRIGHTNESS TAG iPod SD Disc eject number ...

Страница 12: ... error count information display count skip CD DA error count number information CD DA error count numbers XX numbers of errors and when there is none Can only be checked via debugger by jap member CD ROM compressed file error count numbers XX numbers of errors and when there is none Can only be checked via debugger by jap member CD time code error count information display no count update CD time...

Страница 13: ... is not detected in case that none of capacitor leakage wrong con nection or other detection is found D C E R R D C O K Operation Display content Detail UP DC ERR1 display When wrong connection DC error in other detection duration is detected When wrong connection DC error in other detection duration is not detected UP DC ERR1 clear Clear detection information when wrong connection DC er ror in ot...

Страница 14: ...0th error occurred in Mis connect detection period judge as Mis connect If detected error 10 consecutive times and 10th error occurred in Capacitor leak detection period judge as Capacitor leak If detected error 10 consecutive times and 10th error occurred in Other detection period and detected another 10 errors con secutively then judge as Other If judge as Mis connect turn off speaker output dis...

Страница 15: ... No MA511 Rev 001 15 16 SECTION 5 TROUBLESHOOTING This service manual does not describe TROUBLESHOOTING ...